Chengdu Ebyte Electronic Technology Co.,Ltd
E800-DTU(433Lxx-485)-V8 UserManual
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd
3
Step 4: If the customer needs to switch the working mode, it can be controlled by the Mode button to switch between different
working modes (M0 indicator light, M1 indicator light). Press and hold the Mode button for 1 second and then release it to
switch the mode once. The details of the mode switch are shown in the following table:
Categories
M0
M1
Description
Mode 0
Normal Mode
OFF
OFF
Open UART and RF
,
transparent transmission is on
( factory default )
Mode 1
Wake-up
Mode
ON
OFF
Transmitting WOR mode, the packet comes with a
preamble code
Mode 2
Power-saving
Mode
OFF
ON
Receiving WOR mode, saving receive power, the mode
can not be transmitted
Mode 3
Sleep Mode
ON
ON
Parameter setting using the configuration software
Note: The DTU has the function of power-down saving mode (the factory default setting is transparent transmission
mode), the user needs to switch the corresponding mode according to the M1 and M0 indicators (effective
immediately).