Chengdu Ebyte Electronic Technology Co,;Ltd
E70-433T14S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
15
Configuring
Parameter configuration can be made in configuration mode with specific instruction format and UART 9600,
8N1.
Note
When entering other modes from configuration mode, the module will reconfigure parameters, AUX keeps
low level during configuration;
After configuration completed, it outputs high level, so users are recommended to check the AUX rising edge.
6.6 Wake-up Mode (Mode 4)
Status
M0=0 M1=0 M2=1
Transmitting
Transmission is available.
Receiving
Receiving is not available.
Baud rate & air
data rate
Under this mode, the baud rate and air data rate are independent, both receiver and transmitter can have
different baud rate but same air data rate.
Advantage
It can wake up the receiver under mode 6; wake up code will be added automatically before transmitting, the
code number depends on the wake up time.
Disadvantage
The transmission time is long, only applicable to wake up the receiver, not applicable for common data
transmission.
Applications
For waking up the receiver under WOR mode.
Note
Under wake up mode, the single data packet length is 84 bytes (excluding the address and channel for
directional transmission).
6.7 Configuration Mode (Mode 5)
Status
M0=1 M1=0 M2=1
Transmitting
Transmission is not available. Serial data received are considered as configuration command.
Receiving
Receiving is not available.
Configuration
Parameter configuration can be made in configuration mode with specific instruction format and UART 9600,
8N1.
Note
When entering other modes from configuration mode, the module will reconfigure parameters, AUX keeps low
level during configuration;
After configuration completed, it outputs high level, so users are recommended to check the AUX rising edge.
6.8 Power Saving Mode (Mode 6)
Status
M0=0 M1=1 M2=1
Transmitting
Transmission is not available.