Chengdu Ebyte Electronic Technology Co,;Ltd
E70-433T14S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
18
0
1
8O1
1
0
8E1
1
1
8N1
(
equal to 00
)
5
4
3
TTL UART baud rate
(
bps
)
UART baud rate can be different between
communication parties
The UART baud rate has nothing to do with
wireless transmission parameters & won’t affect
the wireless transmit / receive features.
0
0
0
1200bps
0
0
1
2400bps
0
1
0
4800bps
0
1
1
9600bps
(
Default
)
1
0
0
19200bps
1
0
1
38400bps
1
1
0
57600bps
1
1
1
115200bps
2
1
0
Air data rate
(
bps
)
The lower the air data rate, the longer the
transmitting distance, better anti-interference
performance and longer transmitting time
The air data rate must keep the same for both
communication parties.
0
0
0
2.5kbps
0
0
1
5kbps
0
1
0
12kbps
(
Default
)
0
1
1
28kbps
1
0
0
64kbps
1
0
1
168kbps
1
1
0
168kbps
1
1
1
168kbps
4
CHAN
7
6
5
Packet length (only for sub-package
mode)
Under continuous transmitting mode (M0=1 M1=0
M2=0), this parameter is invalid
0
0
0
16 bytes
0
0
1
32 bytes
0
1
0
64 bytes
(
Default
)
0
1
1
128 bytes
1
0
0
256 bytes
1
0
1
512 bytes
1
1
0
1024 bytes
1
1
1
2048 bytes
Communication Channel
00H~1FH, 861~876.5MHz
,(
Default
)
04H
(
433M
)
5
OPTION
7
Fixed transmission (similar to MODBUS
)
When it is 1, the first three bytes of each user data
frame can be used as high/low address and
channel. The module changes its address and
channel when transmitting. And it will revert to
original setting after the process is completed.
It is transparent transmission under continuous
mode.
0
Transparent transmission mode (Default
)
1
Fixed transmission mode
6
5
4
wireless wake-up time
This parameter is only valid for mode 4, 6.