background image

SI4438 Wireless Module

User Manual of E30 Series Modules

Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.

4

/

17

1. Features

Ultra-low power consumption:

It supports WOR, which suits for battery power supply. In power-saving mode (Mode 2), the overall

power consumption can be regulated by setting receiving response delay and its maximum is 2000ms. The average current is about

30uA.

Fixed transmission:

Module can communicate with other modules which work in different channels and addresses. It makes

networking and repeater easy. For example: module A transmits AA BB CC to module B (address: 0x00 01, channel: 0x80). The HEX

format is 00 01 80 AA BB CC (00 01 refers to the address of module B, and 80 refers to the channel of module B). Then module B

receives AA BB CC (only module B).

Broadcast transmission:

When the module address is set as 0xFFFF, the module can communicate with other modules in the

same channel.

FEC:

Forward Error Correction has high coding efficiency & good correction performance. In case of sudden interference, it can

correct the interfered data packets proactively, so that the reliability & transmission range are improved correspondingly. Without

FEC, those data packets can only be dropped.

Sleep mode:

When the module works in sleep mode (Mode 3), it is available for configuration, but not for transmitting &

receiving. The typical current is 2.0uA in this mode.

Application:

Compared with 2.4G, it is better in penetration and diffraction but less in speed rate. It is applicable in the open air

and places with a few obstacles.

2. Technical Parameters

Model

IC

Size

Net weight

Operating

temperature

Operating

humidity

Storage

temperature

E30-TTL-100

SI4438

21 * 36 mm

6.7±0.1g

-40 ~ 85℃

10% ~ 90%

-40 ~ 125°C

E30-T100S2

SI4438

17 * 30 mm

2.3±0.1g

-40 ~ 85℃

10% ~ 90%

-40 ~ 125°C

2.1 E30-TTL-100/ E30-T100S2

Parameter

Min

Typ

Max

Unit

Transmitting current

82

89

98

mA

Receiving current

15

16

17

mA

Turn-off current

3

4

5

μA

Transmitting power

19.3

20

20.6

dBm

Receiving sensitivity

-120

-121

-122

dBm

Voltage supply

2.3

3.3

5.2

V

Communication level

2.5

3.3

3.6

V

Содержание E30-TTL-100

Страница 1: ...odule E30 Series This manual may be modified based on product upgrade please refer to the latest version All rights to interpret and modify this manual belong to Chengdu Ebyte Electronic Technology Co...

Страница 2: ...TL level WOR ultra low power consumption They feature half duplex and two kinds of interface SMD and DIP The module has the function of data encryption compression The data of the module transmitted o...

Страница 3: ...eset 9 5 6 AUX Description 9 5 6 1 Indication of UART Output 9 5 6 2 Indication of Wireless Transmitting 9 5 6 3 Configuration Procedure of Module 10 5 6 4 Notes for AUX 10 6 Operating Mode 10 6 1 Mod...

Страница 4: ...ard Error Correction has high coding efficiency good correction performance In case of sudden interference it can correct the interfered data packets proactively so that the reliability transmission r...

Страница 5: ...urrent may be higher for some RF chips with communication protocol or when the developers have loaded their own protocol to the whole module The current at pure receiving mode is at mA level To achiev...

Страница 6: ...ART inputs connects to external MCU PC TXD output pin Can be configured as open drain or pull up input 4 TXD Output TTL UART outputs connects to external RXD MCU PC input pin Can be configured as open...

Страница 7: ...connects to external RXD MCU PC input pin Can be configured as open drain or push pull output 5 AUX Output To indicate module s working status wakes up the external MCU During the procedure of self ch...

Страница 8: ...e address of module A as 0xFFFF or 0 x0000 and channel as 0x04 When module is the transmitter transparent transmission all modules under channel 0x04 will receive the data the purpose of broadcast is...

Страница 9: ...ta that are not sent yet via wireless way or whether all wireless data has been sent through UART or whether the module is still in the process of self check initialization 5 6 1 Indication of UART Ou...

Страница 10: ...be switched immediately When the user switches to other operating modes from mode 3 sleep mode or it s still in reset process the module will reset user parameters During it AUX outputs low level 6 Op...

Страница 11: ...change so that the mode switch can be realized This operation is very flexible and efficient It is totally designed on the basis of the user MCU s convenience at the same time the work load and power...

Страница 12: ...module works in mode 3 Transmitting N A Receiving N A Parameter setting This mode can be used for parameter setting It uses serial port 9600 8N1 to set module working parameters through specific inst...

Страница 13: ...ersion number for example C3 30 xx yy 30 here means the module model E30 series xx is the version number and yy refers to the other module features 7 4 Reset Instruction Instruction format Description...

Страница 14: ...irst three bytes of each user s data frame can be used as high low address and channel The module changes its address and channel when transmit And it will revert to original setting after complete th...

Страница 15: ...e the ability of current output more than 250mA and ensure the power supply ripple within 100mV Low power transmission is not recommended due to its low power supply efficiency 0 0 20dBm Default 0 1 1...

Страница 16: ...Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max L...

Страница 17: ...to antenna quality or poor matching between antenna and module 10 2 Module is easy to damage Please check the power supply and ensure it is within the recommended range Voltage higher than the peak w...

Отзывы: