background image

SI4438 Wireless Module

User Manual of E30 Series Modules

Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.

17

/

17

10. FAQ

10.1 Communication range is too short

The communication distance will be affected when obstacle exists.

Data lose rate will be affected by temperature, humidity and co-channel interference.

The ground will absorb and reflect wireless radio wave, so the performance will be poor when testing near ground.

Seawater has great ability in absorbing wireless radio wave, so performance will be poor when testing near the sea.

The signal will be affected when the antenna is near metal object or put in a metal case.

Power register was set incorrectly, air data rate is set as too high (the higher the air data rate, the shorter the distance).

When the power supply at room temperature is lower than the recommended low voltage, the lower the voltage is, the lower the

transmitting power is.

Due to antenna quality or poor matching between antenna and module.

10.2 Module is easy to damage

Please check the power supply and ensure it is within the recommended range. Voltage higher than the peak will lead to a

permanent damage to the module.

Please check the stability of power supply and ensure the voltage not to fluctuate too much.

Please make sure anti-static measures are taken when installing and using, high frequency devices have electrostatic susceptibility.

Please ensure the humidity is within limited range for some parts are sensitive to humidity.

Please avoid using modules under too high or too low temperature.

11. Important Notes

All rights to interpret and modify this manual belong to Ebyte.

This manual will be updated based on the upgrade of firmware and hardware, please refer to the latest version.

Please refer to our website for new product information.

12. About Us

Technical support:

[email protected]

Documents and RF Setting download link:

www.cdebyte.com/en/

Tel:+86-28-61399028

Fax:028-64146160

Web:

www.cdebyte.com/en/

Address:Innovation Center D347, 4# XI-XIN Road, Chengdu, Sichuan, China

Содержание E30-TTL-100

Страница 1: ...odule E30 Series This manual may be modified based on product upgrade please refer to the latest version All rights to interpret and modify this manual belong to Chengdu Ebyte Electronic Technology Co...

Страница 2: ...TL level WOR ultra low power consumption They feature half duplex and two kinds of interface SMD and DIP The module has the function of data encryption compression The data of the module transmitted o...

Страница 3: ...eset 9 5 6 AUX Description 9 5 6 1 Indication of UART Output 9 5 6 2 Indication of Wireless Transmitting 9 5 6 3 Configuration Procedure of Module 10 5 6 4 Notes for AUX 10 6 Operating Mode 10 6 1 Mod...

Страница 4: ...ard Error Correction has high coding efficiency good correction performance In case of sudden interference it can correct the interfered data packets proactively so that the reliability transmission r...

Страница 5: ...urrent may be higher for some RF chips with communication protocol or when the developers have loaded their own protocol to the whole module The current at pure receiving mode is at mA level To achiev...

Страница 6: ...ART inputs connects to external MCU PC TXD output pin Can be configured as open drain or pull up input 4 TXD Output TTL UART outputs connects to external RXD MCU PC input pin Can be configured as open...

Страница 7: ...connects to external RXD MCU PC input pin Can be configured as open drain or push pull output 5 AUX Output To indicate module s working status wakes up the external MCU During the procedure of self ch...

Страница 8: ...e address of module A as 0xFFFF or 0 x0000 and channel as 0x04 When module is the transmitter transparent transmission all modules under channel 0x04 will receive the data the purpose of broadcast is...

Страница 9: ...ta that are not sent yet via wireless way or whether all wireless data has been sent through UART or whether the module is still in the process of self check initialization 5 6 1 Indication of UART Ou...

Страница 10: ...be switched immediately When the user switches to other operating modes from mode 3 sleep mode or it s still in reset process the module will reset user parameters During it AUX outputs low level 6 Op...

Страница 11: ...change so that the mode switch can be realized This operation is very flexible and efficient It is totally designed on the basis of the user MCU s convenience at the same time the work load and power...

Страница 12: ...module works in mode 3 Transmitting N A Receiving N A Parameter setting This mode can be used for parameter setting It uses serial port 9600 8N1 to set module working parameters through specific inst...

Страница 13: ...ersion number for example C3 30 xx yy 30 here means the module model E30 series xx is the version number and yy refers to the other module features 7 4 Reset Instruction Instruction format Description...

Страница 14: ...irst three bytes of each user s data frame can be used as high low address and channel The module changes its address and channel when transmit And it will revert to original setting after complete th...

Страница 15: ...e the ability of current output more than 250mA and ensure the power supply ripple within 100mV Low power transmission is not recommended due to its low power supply efficiency 0 0 20dBm Default 0 1 1...

Страница 16: ...Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max L...

Страница 17: ...to antenna quality or poor matching between antenna and module 10 2 Module is easy to damage Please check the power supply and ensure it is within the recommended range Voltage higher than the peak w...