5.6.3 Configuration procedure of module
Only happened when power-on resetting or exiting sleep mode
5.6.4 Notes for AUX
No.
Description
1
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means if it
meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX outputs
high level.
2
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms since AUX
outputs high level, the mode switch will be completed.
3
After switching to new operating mode, it will not work in the new mode immediately until AUX rising edge lasts for 2ms . If
AUX stays on the high level, the operating mode switch can be effected immediately.
4
When the user switches to other operating modes from mode 3 (sleep mode) or it’s still in reset process, the module will reset
user parameters, during which AUX outputs low level.
6. Operating mode
There are four operating modes, which are set by M1 and M0, the details are as follows:
Mode(0-3)
M1
M0
Description
Remark
0 Normal mode
0
0
UART and wireless channel are open, transparent transmission
is on
The receiver must work in
mode 0 or mode 1
1 Wake-up
0
1
UART and wireless channel are open. The difference between
normal
mode and wake-up mode is that it will add preamble code
automatically before data packet transmission so that it can
awaken
the receiver works in mode 2
The receiver can work in
mode 0, mode 1 or mode 2
2 Power-saving Mode
1
0
Users can access the register through the serial port to control
the working state of the module
1. The transmitter must
work in mode 1
2. Transmitting is not
allowed in this mode
3 sleep mode
1
1
Parameter setting
More in working parameter