Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
3-24
Example
:
F0E1D2C3B4A5
Description:MAC address displays as hexadecimal ASCII
6.24 Query the MAC address of the connected device
Command
Response
Parameter
Query
:
AT+PEERMAC?
+OK=[para]
para:MAC address
Example
:
F0E1D2C3B4A5
Description: ASCIIImmediately It takes effect immediately, can only be used when connecting, otherwise an error is
returned and the MAC address displays as hexadecimal ASCII
6.25 Read MAC binding status, enable or disable MAC binding
Command
Response
Parameter
Query
:
AT+BONDEN?
+OK=[para]
para:0,1
0
:
Binding disabled
1
:
Binding enabled
Setting
:
AT+ BONDEN =[para]
+OK
:
Success
+ERR=[NUM]
:
Error
Description
:
Restart to take effect, save when power off
6.26 Read and set binding MAC
Command
Response
Parameter
Query
:
AT+BONDMAC?
+OK=[para]
para:MAC address
Example
:
F0E1D2C3B4A5
Setting
:
AT+BONDMAC=[para]
+OK
:
Success
+ERR=[NUM]
:
Error
Description
:
Restart to take effect, save when power off, follow the small segment mode, that is, the MAC address high
level is followed, and the MAC address displays as hexadecimal ASCII
For example, set the banding MAC to "F0E1D2C3B4A5"
:
41 54 2B 42 4F 4E 44 4D 41 43 3D F0E1D2C3B4A5
6.27 Query and set the MTU length
Command
Response
Parameter
Query
:
AT+MTU?
+OK=[para]
para:27~230
Setting
:
AT+MTU=[para]
+OK
:
Success
+ERR=[NUM]
:
Error
Description
:
It takes effect on next connection, save when power off