Chengdu Ebyte Electronic Technology Co.,Ltd.

E104-BT51 User Manual

Copyright ©2012–2019

Chengdu Ebyte Electronic Technology Co.,Ltd.

9-42

Please pay attention to the correct connection of the positive and negative poles of the power supply. Reverse
connection may cause permanent damage to the module;

Please check the power supply to ensure it is within the recommended voltage otherwise when it exceeds the
maximum value the module will be permanently damaged;

Please check the stability of the power supply, the voltage can not be fluctuated frequently;

When designing current supply circuit, 30% margin is recommended to be remained so as to ensure long-term
stable operation of the whole module;

The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference;

High-frequency digital routing, high-frequency analog routing, and power routing must be avoided under the
module. If it is necessary to pass through the module, assume that the module is soldered to the Top Layer, and the
copper is spread on the Top Layer of the module contact part(well grounded), it must be close to the digital part of
the module and routed in the Bottom Layer;

Assuming the module is soldered or placed over the Top Layer, it is wrong to randomly route over the Bottom Layer
or other layers, which will affect the module's spurs and receiving sensitivity to varying degrees;

It is assumed that there are devices with large electromagnetic interference around the module that will greatly
affect the performance. It is recommended to keep them away from the module according to the strength of the
interference. If necessary, appropriate isolation and shielding can be done;

Assume that there are traces with large electromagnetic interference (high-frequency digital, high-frequency analog,
power traces) around the module that will greatly affect the performance of the module. It is recommended to stay
away from the module according to the strength of the interference. If necessary, appropriate isolation and shielding
can be done;

If the communication line uses level, 1k-5.1k resistor must be connected in series(not recommended, there is a risk
of damage)

Try to stay from some physical layers such as TTL protocol at 2.4GHz , for example: USB3.0;

The antenna installation structure has a great impact on the performance of the module. Be sure to keep the antenna
exposed, preferably vertically. When the module is installed inside the case, a high-quality antenna extension cable
can be used to extend the antenna to the outside of the case;

The module must not be installed inside metal shield, which will greatly reduce the transmission distance.

10. FAQ

10.1 Communication range is too short

The communication distance will be affected when obstacle exists.

Data lose rate will be affected by temperature, humidity and co-channel interference.

The ground will absorb and reflect wireless radio wave, so the performance will be poor when testing near ground.

Seawater has great ability in absorbing wireless radio wave, so performance will be poor when testing near the sea.

The signal will be affected when the antenna is near metal object or put in a metal case.

Power register was set incorrectly, air data rate is set as too high (the higher the air data rate, the shorter the
distance).

When the power supply at room temperature is lower than the recommended low voltage, the lower the voltage is,

Содержание E104-BT51

Страница 1: ...E104 BT51 User Manual CC2640R2F BLE5 0 Low power consumption Bluetooth to serial port module...

Страница 2: ...RATION 14 5 11 BROADCAST DATA CAN BE SWITCHED 14 5 12 CONFIGURATION OVER AIR 15 5 13 STATUS OR EVENT PRINTING 16 6 OPERATION COMMAND 16 6 1 AT COMMAND TEST 18 6 2 READ AND CONFIGURE BAUD RATE 18 6 3 R...

Страница 3: ...6 32 QUERY ENABLE DISABLE SERIAL PORT DELAY 26 6 33 RESTART COMMAND 26 6 34 RESTORE FACTORY 26 6 35 AUTHENTICATE CONFIGURATION OVER AIR PASSWORD 26 6 36 UPDATE AND QUERY CONFIGURATION OVER AIR PASSWOR...

Страница 4: ...r Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 3 11 WELDING OPERATION GUIDANCE 43 11 1 REFLOW SOLDERING TEMPERATURE 43 11 2 REFLOW SOLDERING CURVE 44 12 RELATED MODELS 44 13 B...

Страница 5: ...automation home security personal health care smart appliances accessories and remote control automotive electronics lighting industry industrial internet smart data collection smart control etc The...

Страница 6: ...upply V 0 3 6 Voltage over 3 8V will cause permanent damage to module Blocking power dBm 10 Chances of burn is slim when modules are used in short distance Operating temperature 40 85 Industrial grade...

Страница 7: ...up no broadcast current Default 1570 Unit uA Wake up connection current Default 2301 Unit uA Connection interval is 1s Sleep connection current Default 259 1 Unit uA Connection interval is 1s Main par...

Страница 8: ...d 2 GND Ground connected to power supply reference ground 3 GND Ground connected to power supply reference ground 4 DIO_0 Input Output General IO port sensor controller see CC26xx manual for details r...

Страница 9: ...ed Baseboard button 25 DIO_19 Input Output INGPIO0 26 DIO_20 Input Output INGPIO1 27 GND Ground connected to power supply reference ground 28 DIO_21 Input Output INGPIO2 29 VCC Power supply 1 8 3 8V 3...

Страница 10: ...en up the WAKEUP SLEEP DIO_12 pin should be connected to a low level or a falling edge signal should be given to the pin in time If you need to switch between AT configuration mode and transparent tra...

Страница 11: ...nter the wakeup WAKEUP mode The WAKEUP SLEEP DIO_12 pin is initialized to a high level by default If no operation is performed on this pin the module powers on and enters the low power consumption SLE...

Страница 12: ...the GPIOG output refer to command 6 41 setting and read IO output 5 5 PWM Output The E104 BT51 module considers the comprehensiveness of the user s use and the level control mode may not meet the requ...

Страница 13: ...be tested to the detection pins DIO_23 DIO_24 and then ground the module 5 7 Battery voltage service The E104 BT51 module in order to enable the battery voltage to be obtained in a timely manner and...

Страница 14: ...the maximum battery voltage 6 47 Setting and querying the minimum battery voltage Note This module does not need to do voltage division or other operations just connect the positive electrode of the b...

Страница 15: ...may be a set MTU length that does not take effect after connection which is normal 5 10 UUID Configuration The module supports flexible UUID configuration You can command AT UUIDTYPE 1 to enable the...

Страница 16: ...the use of the mobile phone APP program BLE test tool to implement wireless configuration of the module without using the serial debugging assistant The E104 BT51 module supports configuration over ai...

Страница 17: ...command mode in the unconnected state At this time the serial data will be treated as AT commands the module is in the wake up mode when the module is connected if you want to configure AT you need t...

Страница 18: ...r E104 BT51 Default parameter Device name E104 BT51_V1 0 Broadcast data CDEBYTE Configuration over air password 123456 version No V1 0 IBC_Major 1027 IBC_Minor 507 2 byte service UUID 0xF0 0xFF 16 byt...

Страница 19: ...s PWM duty cycle 50us GPIO output Low level 0 6 1 AT Command test Command Response Parameter AT OK No Description No 6 2 Read and configure baud rate Command Response Parameter Query AT BAUD OK para p...

Страница 20: ...to take effect save when power off 6 5 Set and read serial data length Command Response Parameter Query AT DATALEN OK para para 2 3 2 Data length 7 3 Data length 8 Setting AT DATALEN para OK Success...

Страница 21: ...X 2 Length is no longer than 26bytes Setting AT ADVDATA1 para OK Success ERR NUM Error Description It takes effect on next broadcast do not save when power off can be sent as a string or hexadecimal F...

Страница 22: ...wer down Command Response Parameter Query AT NAME OK para para Broadcast device name Broadcast name is not larger than 25 bytes Setting AT NAME para OK Success ERR NUM Error Description It takes effec...

Страница 23: ...he minimum connection interval Command Response Parameter Query AT CONMININTV OK para para 6 3200 Example 8 8 1 25ms 10ms Setting AT CONMININT para OK Success ERR NUM Error Description It takes effect...

Страница 24: ...K para para 0 500 Setting AT CONLATENCY para OK Success ERR NUM Error Description It takes effect on next connection save when power off Note Delay times connection interval connection timeout Namely...

Страница 25: ...BONDEN OK para para 0 1 0 Binding disabled 1 Binding enabled Setting AT BONDEN para OK Success ERR NUM Error Description Restart to take effect save when power off 6 26 Read and set binding MAC Comman...

Страница 26: ...or example set the two byte UUID to FFFO 41 54 2B 55 55 49 44 53 56 52 3D F0FF For example the sixteen byte UUID is 11223344556677889900AABBCCDDEEFF 41 54 2B 55 55 49 44 53 56 52 3D FFEEDDCCBBAA009988...

Страница 27: ...a para 0 1 0 Disabled 1 Enabled Setting AT DELAYDATA para OK Success ERR NUM Error Description It takes effect immediately save when power off 6 33 Restart command Command Response Parameter AT RESET...

Страница 28: ...ponse Parameter Query AT TRANSPWR OK para para 0 9 0 21dBm 1 18dBm 2 15dBm 3 12dBm 4 9dBm 5 6dBm 6 3dBm 7 0dBm 8 1dBm 9 2dBm A 3dBm B 4dBm C 5dBm Setting AT TRANSPWR para OK Success ERR NUM Error Desc...

Страница 29: ...rameter Query AT OUTGPIO OK para para 0 F Hexadecimal code Setting AT OUTGPIO para OK Success ERR NUM Error Description It takes effect immediately save when power off OUTGPIO3 2 1 0 0000 which means...

Страница 30: ...can also be different 6 45 Query ADC sampling value Command Response Parameter Query AT ADCx OK para para 0 4096 x No Setting AT ADCx para OK Success ERR NUM Error Description 12 bit ADC acquisition o...

Страница 31: ...only notify This channel is the module receiving the serial data channel and returns to the Bluetooth host in a notified manner The maximum data length of a single packet is 251 bytes Description If...

Страница 32: ...onfiguration mode or use other software with serial port sending and receiving 1 Open XCOM V2 0 exe software find the corresponding serial port number open it and select the parameters according to th...

Страница 33: ...essful perform step 2 2 After successfully installing the APP in step 1 open BLE Scanner find the E104 BT51_V1 0 module and click E104 BT51_V1 0 to connect the module After the connection is establish...

Страница 34: ...nt transmission channel In the picture 1 is the notification channel 2 is the write channel and 3 is the configuration over air channel 4 After step 3 is successful click to enter service 1 and then c...

Страница 35: ...Chengdu Ebyte Electronic Technology Co Ltd E104 BT51 User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 8 34...

Страница 36: ...Electronic Technology Co Ltd 8 35 Open mobile APP notification Mobile APP receiving data 5 Click W button of service 2 as shown in step 3 to enter the write operation After editing the content click O...

Страница 37: ...Chengdu Ebyte Electronic Technology Co Ltd E104 BT51 User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 8 36 Mobile APP sending data...

Страница 38: ...k N button at service 3 to turn on the configuration over air notification function and then click W button to enter the configuration over air mode In the configuration over air password needs to be...

Страница 39: ...ctronic Technology Co Ltd E104 BT51 User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 8 38 After passing the password authentication of configuration over air Return OK to sta...

Страница 40: ...Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 8 39 After successful password authentication you will get the returning message 0K At this point you can perform configuration ov...

Страница 41: ...lection pin 34 of the module to the battery to be tested After connecting the device according to Section 8 2 click Battery Service and then click N button under the service to enable the notification...

Страница 42: ...o Ltd 9 41 For details please refer to 6 46 Setting and Reading the Maximum Battery Voltage and 6 47 Setting and Querying the Minimum Battery Voltage 9 Hardware design It is recommended to use a DC st...

Страница 43: ...odule according to the strength of the interference If necessary appropriate isolation and shielding can be done Assume that there are traces with large electromagnetic interference high frequency dig...

Страница 44: ...or some parts are sensitive to humidity Please avoid using modules under too high or too low temperature 10 3 Bit error rate is too high When there are co channel signal interference nearby be away fr...

Страница 45: ...0 Aveage ramp down rate Tp to Tsmax Average descent rate 6 second max 6 second max Time 25 to peak temperature Time of 25 C to peak temperature 6 minutes max 8 minutes max 11 2 Reflow Soldering Curve...

Страница 46: ...X Hardware resources secondary development E104 BT01 CC2541 2 4G 0 I O 4 0 14 22 PCB Hardware resources secondary development E104 BT02 DA14580 2 4G 0 TTL 4 2 14 22 PCB Industry s lowest power consump...

Страница 47: ...2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 14 46 consumption battery service transparent transmission PWM output IO output IO acquisition ADC acquisition 13 Batch packaging 14 Revision hist...

Страница 48: ...yright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 15 47 15 About us Sales hotline 4000 330 990 Tel 028 61399028 Support support cdebyte com Website www ebyte com Address Innovation Center B3...

Отзывы: