6.4.23 AT+PWR Transmitting Power
Command
Response
Inquire
AT+ PWR?
+OK=[para]
Set
AT+ PWR =[para]
+OK
:
success
+ERR=[NUM]
:
error
parameter
para(ASCII)
val
0
4 dBm
1
3 dBm
2
0 dBm (default)
3
-4 dBm
4
-8 dBm
5
-12 dBm
6
-16 dBm
7
-20 dBm
8
-40 dBm
Description
Take effect immediately and save after power failure
6.4.24 AT+SLEEP Enter Sleep Command Immediately
Command
Response
Set
AT+SLEEP
+OK
parameter
No
Description
Effective immediately.
6.4.25 AT+LOGMSG Operation Status Output
Command
Response
Inquire
AT+LOGMSG?
+OK=[para]