parameter
Intv: is the scan gap,
Wnd: scan window
Description
1. Take effect immediately, save when
power off,
2. The scanning gap is not less than the
scanning window
3. The slave does not support it, but it can
still be set
Sample
6.4.21 AT+AUTH Air Configuration Authentication Password
Command
Response
Set
AT+AUTH =[para]
+OK
:
success
+ERR=[NUM]
:
error
parameter
para(HEX): 6-byte password
Description
This directive is only used for air certification.
Default password (ASCII): 123456
After successful authentication, this command is not available.
Sample
AT+AUTH=123456
6.4.22 AT+UPAUTH Modify Air Authentication Password
Command
Response
Inquire
AT+UPAUTH
?
+OK=[para]
Set
AT+UPAUTH =[para]
+OK
:
success
+ERR=[NUM]
:
error
parameter
para(HEX): 6-byte password
Description
Effective immediately. Power-down save