Chengdu Ebyte Electronic Technology Co., Ltd.
E104-BT06 User Manual
Copyright ©2012–2018
,
Chengdu Ebyte Electronic Technology Co., Ltd
6.4.13 AT+IPWR Modify ibeacn tx_power
Instruction
React
Inquiry
AT+IPWR?
+OK=[para]
Setting
AT+ IPWR =[para]
+OK
:
Done
+ERR=[NUM]
:
Error
Parameter
para(HEX)
:
0-0XFF
Default
:
0
Description
1. Take effect immediately (if the broadcast is not turned on, or it will take effect next time if
connected), save when power off
2. The slave or master-slave integrated supports broadcasting, other roles can still be
configured;
6.4.14 AT+NAME Broadcast Device Name
Instruction
React
Inquiry
AT+NAME?
+OK=[para]
Setting
AT+NAME=[para]
+OK
:
Done
+ERR=[NUM]
:
Error
Setting
((do not
save))
AT+NAME1=[para]
Parameter
para(HEX): broadcast device name,
Broadcast name is not more than 22 bytes
Default: E104-BT52-V1.0
Description
1.Take effect immediately, save when power off;
2.Only supported by the slave, other roles can still be configured;
6.4.15 AT+DISCON Disconnect Instruction
Instruction
React
Setting
AT+DISCON
+OK
:
Done
+ERR=[NUM]
:
Error
Disconnect all AT+DISCON
+OK
:
Done
+ERR=[NUM]
:
Error
Parameter
Description
Take effect immediately.
6.4.16 AT+MAC Local MAC Address
Instruction
React
Inquiry
AT+MAC?
+OK=[para]
Parameter
para
(
HEX
)
:MAC Address
E.g
:
F0E1D2C3B4A5