Chengdu Ebyte Electronic Technology Co., Ltd.
E104-BT06 User Manual
Copyright ©2012–2018
,
Chengdu Ebyte Electronic Technology Co., Ltd
Smart home
Industrial remote control and telemetry;
Intelligent buildings, intelligent buildings;
Automated data collection;
Health sensor
Smart robot;
Wireless sensing
Electronic label;
Intelligent control;
Chapter 2 Specifications
2.1 Limit parameters
M
ain parameters
Performance
Re
m
ark
Min
Max
Power supply voltage (V)
2
3.6
Over 3.6V will permanently burn the module
2.2 Operating parameter
Main parameter
Performance
Remark
Min
Type
Max
Operating voltage
(
V
)
2.0
3.3
3.6
≥
3.3V can guarantee output power
Communication level (V)
-
3.3
-
Using 5V level is risky to burn
Operating frequency
(
Mhz
)
2402
-
2480
Applicable ISM frequency band
Power
consumption
Emission current (mA)
-
30.4
-
Peak emission
Receiving current (mA)
-
-
-
-
Sleep current (
μ
A)
-
9
-
Default parameters
Transmit power (dBm)
-15
0
3
-
Receiving sensitivity (dBm)
-
-85
-
Chip manual parameters
Sleep broadcast current (default)
-
194.62
-
Unit : uA. Default broadcast interval 1S
Wake-up broadcast current (default)
-
6.9
-