Chengdu Ebyte Electronic Technology Co., Ltd.
E104-BT06 User Manual
Copyright ©2012–2018
,
Chengdu Ebyte Electronic Technology Co., Ltd
Instruction
React
AT
+OK
Description: None
6.4.2 AT+RESET reset command
Instruction
React
AT+RESET
+OK
Description: effective immediately
6.4.3 AT+RESTORE restore factory command
Instruction
React
AT+RESTORE
OK
Description:
1
、
After resetting, it will restart automatically;
2、
In the process of restoring factory settings, any form of reset is prohibited, and the power off before the
operation is completed is prohibited;
6.4.4 AT+BAUD serial port baud rate
Instruction
React
Inquire
AT+BAUD?
+OK=[para]
Setting
AT+BAUD=[para]
+OK
:
Done
+ERR=[NUM]
:
Error
Parameter
para
(
ASCII
)
Baud rate(bps)
0
230400
1
120800
2
115200
(
Default
)
3
760800
4
57600
5
19200
6
9600
7
4800
8
2400
Description
Restart to take effect.