Chengdu Ebyte Electronic Technology Co., Ltd.
E831-RTU (6060-ETH) User Manual
40080
(0x004F)
1
Check digits
Read/writ
e
0 - 2
0x00
40081(0x0050
)
1
Master mode or slave
mode
Read/writ
e
0 - 1
0x01
40082
(0x0051)
1
The switch is
automatically
reported
Read/writ
e
0 - 2
0x00
40083
(0x0052)
1
On-off output time
setting
( ms) .
Read/writ
e
300-65535
--
retain
40085
(0x0054)
1
The on-off amount
restart
output status
setting
Read/writ
e
0x00 - 0x40
0x40
0x03
0x06
0x10
retain
40098
(0x0061)
6
Device MAC address
read only
--
--
0x03
0x06
0x10
40104
(0x0067)
1
Ethernet reboots
Read/writ
e
--
--
40108
(0x006B)
14
WAN port IP
information
Read/writ
e
--
Static IP
192.168.4.101
255.255.255.0
192.168.4.1
40122
(0x0079)
8
Set the DNS
information
Read/writ
e
--
61.139.2.69
192.168.4.1
40130
(0x0081)
8
Set the network
protocol parameters
Read/writ
e
--
TCPS,192.168.4.
10,
8886
40146
(0x0091)
2
Set up a
registration package
mode
Read/writ
e
0-4
Close the
enrollment
package
(0x00)
40150
(0x0095)
42
Set up the
registration package
content
Read/writ
e
--
regist msg
40234
(0x00E9)
42
Set the heartbeat
pack contents
Read/writ
e
--
heartbeat msg
40318
(0x013D)
2
Set the heartbeat
packet mode
Read/writ
e
0-1
Mesh heartbeat
packet
(0x00)
40322
(0x0141)
2
Set the heartbeat
package time
Read/writ
e
0
、
2-65535
0x00
40330
(0x0149)
2
Set up a cache
clear
Read/writ
e
0-1
Cached data for
socket A1
links
is not
cleared
40336
(0x014F)
6
Set the kee p-alive
parameter
Read/writ
e
--
Detection time
10s
Probe interval 5s
The number of
probes is 30
40350
(0x015D)
2
Set the local port
number
Read/writ
e
0-65535
8886
40354
(0x0161)
2
Set up a cloud
transmission
function
Read/writ
e
0-1
Shut down
40356
(0x0163)
2
Sets a timeout
restart time
Read/writ
e
60-65535
3600
40358
(0x0165)
8
SN code
read
--
--