![EBS EPX400 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/ebs/epx400/epx400_installation-and-programming-manual_530167007.webp)
EPX400 – Manual
Page 7 / 71
Charging module functions
- protection against reverse battery connection
- AC failure signalization
- low battery/no battery signalization
- protection against short circuit battery output
- polymer fuse
Backup battery connection
YES, lead-acid 12V
Battery charging current
max. 220mA
Threshold of signaling low AC voltage (at
secondary / at primary)
13.5V
AC
/ 160V
AC
(with EBS transformer)
Threshold of signaling low battery voltage
11V
DC
Cut-off battery voltage level
-
Dimension
PCB: 159 x 73 x 35mm
Working temperature
-10ºC … +55ºC
Working humidity
5% … 93%
Standards
- CE
- according with EN 50136-1-1 Grade 3 ATS Class 5