EPX400 – Manual
Page 22 / 71
7.3.4.
File -> Language
Allows for selection of any available languages (determined in attached exterior
language files).
7.3.5.
File -> Connections
Before programming of devices, a connection type shall be defined. It is possible to
do it with two methods:
- locally
- remotely.
7.3.5.1.
Local connection
Local connection means that configuration software (or, in fact, a computer, on which
it is installed) is directly connected to proper terminal of transmitter via special wire
and through RS-232 serial port (GD-PROG) or USB port or Bluetooth (MINI-PROG-BT,
SP-PROG-BT). All channel connection (also USB and Bluetooth) "open" virtual COM
serial ports used in communication control panel-Configurator.
To program device or make any other operations (e.g. reading of device settings,
firmware amendments, etc.) it is necessary firstly to define connection parameters.
For the above purpose you shall use the following window, available after activating
File option from the Main Menu and selecting Connection function or after clicking
icon on a taskbar and opening RS232 tab.
Define:
Name of connection e.g. Local
Choose serial port e.g. COM 1
Click on [Add] button to confirm settings. Connections shall be saved (and inserted in
table). From this time on program shall enable wires connection with device and
reading, and saving of parameters in memory will be possible.
In the next tab "MINI-PROG" (the name derived from the programmer) you have to
also define the connection parameters.