deposits, for example.

7.2 Safety inspection

NOTE
High-voltage test

The integrated EMC filter has Y capacitors. The tripping current
is exceeded when AC testing voltage is applied.
→ Test the device with DC voltage when you perform the

legally required high-voltage test. The voltage to be used
corresponds to the peak value of the AC voltage required by
the standard.

7.3 Maintenance interval

What to check

How to check

How often

What action?

Corrosion

Visual inspection At least every

3 months

When there is
heavy
corrosion that
impairs the
explosion
protection, e.g.
in gap
surfaces,
replace the
device.

Contact
protection
cover for
intactness or
damage

Visual inspection At least every

6 months

Repair or
replacement of
device

Device for
damage to
blades and
housing

Visual inspection At least every

6 months

Replacement of
device

Fastening the
cables

Visual inspection At least every

6 months

Fasten

Insulation of
cables for
damage

Visual inspection At least every

6 months

Replace wires

Tightness of
cable gland

Visual inspection At least every

6 months

Retighten,
replace if
damaged

Condensation
drainage holes
for clogging,
where necessary

Visual inspection At least every

6 months

Open holes

Welds for crack
formation

Visual inspection At least every

6 months

Replace device

Cable routing
(fastening)

Visual inspection At least every

6 months

Fasten cables

Cleaning and
preventive
maintenance

Visual inspection At least every

3 months

Remove dirt,
clean device

Ball bearings
for smooth and
noiseless
movement free
of play

acoustic and/or
manual check
by turning rotor
when switched
off, vibration test

At least every
3 months

Replace the
device in the
event of noise,
stiffness or
bearing play.
Have motor
bearings
replaced by
ebm-papst.

Vibration test

See Vibration
test section

At least every
6 months

Cleaning,
repair or
replacement of
device

Check gap
dimensions

See Gap
dimensions
section

At least every
3 months

Replacement of
device

7.4 Vibration check

Regular checks must be made to ensure that the fan is not operated at
impermissibly high vibration levels. On the basis of ISO 14694, the
maximum permissible vibration velocities are specified as follows:

Fan connected to system
with isolation from vibration

Fan connected to system
without isolation from
vibration

Vibration velocity

Vibration velocity

max. 6.3 mm/s

max. 4.5 mm/s

Fig. 9: The vibration velocities are measured in radial direction at the
stator bushing.

The motor bearings are provided with permanent lubrication at the
factory. Experience has shown that under normal operating conditions
the grease therefore only has to be renewed after several years. The
motor must be deactivated in the event of bearing noise. To remedy this,
the motor has to be exchanged or the defective bearings replaced by the
ebm-papst Service department.
A record is to be kept of the routine inspections performed.

Item no. 54001-5-9970 · ENU · Change 272968 · Approved 2022-11-23 · Page 17 / 17

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W3G800-GV01-91

Страница 1: ...ng instructions are available in other languages on our website www ebmpapst com 2 2 SAFETY REGULATIONS AND INFORMATION 2 2 1 Hazard levels for warnings 2 2 2 Staff qualifications 2 2 3 Basic safety r...

Страница 2: ...h the operating instructions Malfunctions and defects that affect safety must always be corrected immediately No modifications additions or conversions are to be made to the device for example changes...

Страница 3: ...d its attachment must always be evaluated in connection with the overall safety concept of the system as a whole 2 8 Emissions WARNING Depending on the installation and operating conditions the sound...

Страница 4: ...rmitted ambient temperature range see Chapter 4 2 Nominal data and Chapter 4 5 Transport and storage conditions Operating the device with all protective devices Using the device only in Zones 1 and 2...

Страница 5: ...max 14 mm tightening torque 6 0 6 Nm standard value depending on cable 5 Terminal box fastening screws M4 x 20 tightening torque 3 5 0 5 Nm 6 Ground connection point M8 functional ground for discharg...

Страница 6: ...in the product drawing Use the fastening components available from ebm papst for assembly At one mounting point the contact washer 4 must also be inserted between the housing and the nut Tighten the...

Страница 7: ...osition Shaft horizontal with cable exit 45 or rotor at bottom rotor at top not permissible Condensation drainage holes On rotor side Mode S1 Motor bearing Ball bearing Technical features Output 10 VD...

Страница 8: ...of safety 4 8 The nameplate Fig 1 Specifications on the nameplate Serial number Designation Explanation YY Year Year e g 11 for production in 2011 WW Week Week calendar week in year of production Six...

Страница 9: ...d to air ducts the connection should be isolated from vibration e g using compensators or similar elements Ensure stress free attachment of the fan to the substructure Check the device for transport d...

Страница 10: ...l indicated on the nameplate see Chapter 5 3 3 Connecting wires to terminals For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross...

Страница 11: ...commended stripped lengths in mm inside terminal box for unshielded cables In this illustration all cable glands are used by way of example The illustration may differ from the actual device design Fi...

Страница 12: ...box screw connections and cable glands have been tightened to the specified torque 5 3 3 1 Replacement of cable glands and screw plugs If you would like to replace cable glands or screw plugs for exam...

Страница 13: ...y settings Factory settings made for the device by ebm papst Mode parameter set 1 PWM control Mode parameter set 2 PWM control Fan device address 01 Max PWM 100 Min PWM 5 Save set value to EEPROM Yes...

Страница 14: ...put of current motor modulation level motor speed adjustable curve SELV 2 Din 2 Digital input 2 Switching parameter sets 1 2 according to EEPROM setting the valid or used parameter set can be selected...

Страница 15: ...sonant frequencies must be determined in the course of fan commissioning Either run through the resonant range as quickly as possible with speed control or find another remedy Operation with excessive...

Страница 16: ...ng cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Line voltage faulty Check line voltage restore power supply Attention The error message...

Страница 17: ...ery 6 months Fasten cables Cleaning and preventive maintenance Visual inspection At least every 3 months Remove dirt clean device Ball bearings for smooth and noiseless movement free of play acoustic...