3.2 Nominal data

Motor

M2E068-DF

Phase

1~

Nominal voltage / VAC

115

Frequency / Hz

60

Method of obtaining
data

me

Valid for approval/
standard

CE

Speed / min

-1

3000

Power consumption / W

120

Power output / W

70

Current draw / A

1.15

Rated torque / Ncm

23

Mean starting torque
/ Ncm

13

Capacitor / µF

12

Capacitor voltage / VDB

220

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

55

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.9 kg

Fan size

68 mm

Rotor surface

Rotor open, painted black

Direction of rotation

Right and left

Degree of protection

IP00

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) with
basic insulation

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1; CE

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

4. CONNECTION AND STARTUP

4.1 Mechanical connection

WARNING
Hot motor housing

Risk of fire
→ Ensure that no combustible or flammable materials are

located close to the motor.

CAUTION
Cutting and crushing hazard when removing motor from
packaging

→ Carefully remove the device from its packaging. Strictly

avoid shocks.

→ Wear safety shoes and cut-resistant safety gloves.

;

Check the device for transport damage. Damaged devices are not to
be installed.

;

Install the undamaged device in accordance with your application.

CAUTION
Possible damage to the device

If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of

installation until all fastening screws have been tightened.

4.2 Electrical connection

DANGER
Voltage on the device

Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.

Item no. 13002-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 4 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M2E068-DF13-79

Страница 1: ...ualifications The device may only be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device...

Страница 2: ...he device so it cannot slip e g by using a lashing strip 1 8 Storage Store the device partially or fully assembled in a dry and weatherproof manner in the original packaging in a clean environment Protect the device against environmental effects and dirt until final installation We recommend storing the device for no longer than one year in order to guarantee trouble free operation and the longest...

Страница 3: ... Product drawing All dimensions in mm 1 Max clearance for screw 5 mm 2 Cable AWG20 6x crimped splices Item no 13002 5 9970 ENU Change 89188 Approved 2016 04 18 Page 3 8 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 4: ...a For screw clearance see Chapter 3 1 Product drawing Secure the screws against unintentional loosening e g use self locking screws Strength class of screws 8 8 Any further mounting data required can be taken from the product drawing 3 5 Transport and storage conditions Use the device in accordance with its degree of protection Max permitted ambient temp for motor transport storage 40 C Min permit...

Страница 5: ...cessive current may occur In addition depending on how the device is installed noises can occur with phase control 4 2 3 Variable frequency drive Please use a variable frequency drive only after consultation with ebm papst For operation with variable frequency drives install sinusoidal filters that work on all poles phase phase and phase ground between the drive and the motor During operation with...

Страница 6: ...ram 1 Clockwise operation 2 Counterclockwise operation U1 black U2 gray Z1 blue Z2 brown TOP 2x white Item no 13002 5 9970 ENU Change 89188 Approved 2016 04 18 Page 6 8 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 7: ...unning smoothly Imbalance in rotating parts Clean the device replace it if imbalance persists after cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Line voltage faulty Check line voltage restore power supply Faulty connection Isolate from supply correct connection see connection diagram Thermal overload protector activated Allow motor to...

Страница 8: ...Metallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets ...

Отзывы: