Operating instructions
K3G560-AP23-90
`
II 2G Ex db eb ib IIB T3 Gb
IBExU14ATEX1122 X /04
`
Translation of the original operating instructions
54006-4-8670
4.6 Electromagnetic compatibility
If several devices are switched in parallel on the supply side
so that the line current of the arrangement is in the range of 16-
75 A, then this arrangement conforms to IEC 61000-3-12
provided that the short-circuit power S
sc
at the connection point
of the customer system to the public power system is greater
than or equal to 120 times the rated output of the arrangement.
It is the responsibility of the installation engineer or operator/
owner of the device to ensure, if necessary after consultation
with the network operator, that this device is only connected to
a connection point with a S
sc
value that is greater than or equal
to 120 times the rated output of the arrangement.
4.7 Ex areas
The device may only be used according to the specifications in the
operating instructions; see Chapter 3. Intended use.
Zone classification
The zones describe how long an explosive atmosphere may be present.
Zones 1 and 2 permit only gases, vapors and mist (no dust) which
occur occasionally to seldom in normal operation.
Equipment categories
The device is approved for Category 2 of Equipment Group II. The
categories define the level of safety.
4.8 The nameplate
Fig. 1: Specifications on the nameplate
Serial number
Designation
Explanation
YY
Year Year, e.g. 11 for production
in 2011
WW
Week Week, calendar week in
year of production
Six-digit number, e.g. 000003
Sequential serial number
Ex marking
`
II 2G Ex db eb ib IIB T3 Gb
Element
Explanation
`
Ex marking according to 2014/
34/EU
II
Equipment group (II --> use
above ground (not mining))
2
Category 2 --> Zone 1,
Category 3 --> Zone 2
G
Ex atmosphere (G --> Gas) (no
dust exposure permissible)
Ex db eb ib
Ignition protection type (db -->
flameproof enclosure, eb -->
enhanced safety, ib --> intrinsic
safety with protection level)
IIB
Explosion group (for gases in
Group IIB)
T3
Temperature class T3, see EN
60079-0
Gb
Equipment protection level
Certificate number IBExU14ATEX1123 X /xx
Element
Explanation
IBExU
Certification body
14
Year of approval
ATEX
according to the ATEX Product
Directive 2014/34/EU
1123
Certificate number
X
The "X" symbol after the
certificate number indicates
special conditions for safe use of
the motors, which can be found
in these operating instructions.
\xx
Supplement to EU prototype test
certificate for the respective type
Special conditions for safe use
●
Flameproof joints are only to be repaired in accordance with the
manufacturer’s design specifications. Repairs based on the values in
EN 60079-1 are not permissible.
●
The cable glands employed are only to be used for fixed installation.
Ensure appropriate strain relief when fitting.
●
When replacing cable and wire entries, note that they must be suitable
for long-term service temperatures between -55°C and +80°C.
●
For ambient temperatures below -20°C, the cables must be suitable
for the corresponding usage temperature.
Item no. 54006-5-9970 · ENU · Change 93219 · Approved 2018-02-08 · Page 7 / 16