ebm-papst BoxFan BF700S-355RT01I2 Скачать руководство пользователя страница 5

ebmpapst Denmark ApS, Vallensbaekvej 21, 2605 Broendby 

+45 4363 1111 

[email protected] 

 

2019.08.01 – page 5 

 

1.8  Emissions 

16. 

WARNING 

Depending on the installation and operating conditions, the sound pressure level may exceed 70 

dB(A). 

Risk of noise-induced hearing loss 

Take appropriate technical safety measures.

 

Protect operating personnel with appropriate safety 

equipment such as hearing protection. 

1.9  Hot surface 

17. 

CAUTION 

High temperature on electronics housing.

 

Risk of burns. 

Ensure sufficient protection against accidental contact. 

 

1.10 Storage 

18. 

Store the device partially or fully assembled in a dry place, protected against the weather and free 

from vibration, in the original packaging in a clean environment. Protect the device against 

environmental effects and dirt until final installation. We recommend storing the device for no longer 

than one year from production date to guarantee trouble-free operation and the longest possible 

service life. The unit must be stored in the temperature range: -40

o

C to +80

o

C. Avoid shocks and 

bumps. When storing or installing, the product must be positioned so that it cannot function as a 

stepping-point for overhauling row spacing for other dangerous machines or installations.

 

1.11 Disposal 

19. 

When disposing of the device make sure to comply with all relevant laws and regulations for the 

country of disposal.

 

1.12 Transport 

20. 

Be careful, fragile content. 

Avoid bumps and shocks during handling as this can result in imbalance and broken bearings. 

-//- 

2. INTENDED USE 

 

21. 

 

The device is exclusively designed as a built-in device for conveying air according to its technical data. 

For any other use, a new risk assessment should be made. 

 

22. 

 

Intended use also includes: 

Moving ordinary clean air (all data is given at a density of 1.2 kg / m

3

). Operation of the unit with all 

necessary safety measures installed. Use according to the operating instructions. 

The product should not be used at speeds the excite the intrinsic frequencies in the cabinet and/or 

suspension as this will cause increased vibration and noise. 

 

 

 

Содержание BoxFan BF700S-355RT01I2

Страница 1: ...akes it resistant to various climate impacts Inside the box the fan is mounted on a warm galvanized sheet metal plate and this is accessed by removing the inspection hatch The fan itself is an EC fan...

Страница 2: ...surface 5 1 10 Storage 5 1 11 Disposal 5 1 12 Transport 5 2 INTENDED USE 5 3 TECHNICAL DATA 6 3 1 Product drawing 6 3 2 Nominal Data 7 3 3 Technical description 8 3 4 Mounting data 8 3 5 Electromagnet...

Страница 3: ...TION Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to property if the specified actions are not taken 4 NOTE A potentially harmful situation can oc...

Страница 4: ...free blowing or free suctioning and is not connected to ducts The protective net must be able to withstand the kinetic energy of an impeller part The unit is a built in component You the owner is res...

Страница 5: ...he longest possible service life The unit must be stored in the temperature range 40o C to 80o C Avoid shocks and bumps When storing or installing the product must be positioned so that it cannot func...

Страница 6: ...under this application 24 Moving air contaminated by dust e g extraction of sawdust Operation of the unit close to combustible materials or components Operation of the device in an explosive atmosphe...

Страница 7: ...x static pressure 880 Pa 1 Nominal data in working point with max load at 230 VAC 26 Additional data PFC Passive LwA Sound effect 87 dB A 2 LpA Sound pressure at 1 m 76 dB A 2 LpA Sound pressure at 3...

Страница 8: ...cordance with the rules of ISO 14118 31 Any emergency stop functions must meet the requirements of ISO 13850 3 5 Electromagnetic compatibility 32 EMC emission EN 61000 6 3 EMC Immunity EN 6100 6 2 Har...

Страница 9: ...e a gap between the supply cable and the control cable when installing these in the application Provide adequate distance Recommendation distance 10 cm separate wiring 39 NOTE Water ingress into wires...

Страница 10: ...asic insulation on supply side and reinforced insulation on control interface side 1 7 COM White 2 Status relay floating status contact common connection contact rating 250 VAC 2A AC1 min 10 mA basic...

Страница 11: ...ominal supply voltage Start the device by changing the input signal 4 8 Switching off the device 46 Switching off the device during operation Switch off the device via the control input to protect it...

Страница 12: ...Lower temp if possible Reset by reducing control signal to 0 VDC Impeller runs unevenly Imbalance in rotating parts Clean the unit and balance it properly If imbalance Is still present the unit is re...

Отзывы: