41)
8.3 Troubleshooting (3) TRIP
Display
Symptom
Check Item
Corrective Action
Exhaust pressure rise
Check exhaust piping
Cooling water decrease
Increase water slowly
Byproduct clog
Replace or overhaul pump
TRIP: CASING
TEMP H.HIGH
Pump casing temp.
rises.
Duct ventilation insufficient Ventilate
sufficiently
Cooling water decrease
Increase water slowly
TRIP: BP MOTOR
TEMP HIGH
TRIP: MP MOTOR
TEMP HIGH
BP motor temp.
rises.
MP motor temp.
rises.
Motor is in failure
Replace or overhaul pump
Exhaust pressure rise
Check exhaust piping
Byproduct clog
Replace or overhaul pump
Object ingestion
Replace or overhaul pump
Instruments are in failure
Replace instruments
TRIP: BP MOTOR
OVERLOAD
TRIP: MP MOTOR
OVERLOAD
BP current rises.
(thermal relay trip)
MP current rises.
(thermal relay trip)
Power supply failure
Check power supply
Incorrect wiring
Wire R/S/T/E correctly
Negative phase
Instruments are in failure
Replace instruments
TRIP:
PHASE ERROR
Open phase
Incorrect wiring
Check power supply
TRIP: BP MOTOR
NO CURRENT
TRIP: MP MOTOR
NO CURRENT
BP motor current value
is 0.
MP motor current value
is 0.
Instruments are in failure
Replace instruments
Starting in ALARM / TRIP
condition
Satisfy all starting
conditions
TRIP: STARTFAIL
ALARM/TRIP EXIST
Start fault
Instruments are in failure
Replace instruments
After taking corrective action, input RESET signal or push RESET button. The pump will
not RESET while the cause of the TRIP remains. In remote operation mode, interrupt
external START signal before resetting.
WARNING
Interrupt Earth Leakage Breaker (ELB) or CB and lock out power
before starting on wiring and maintenance work.
Do not switch on the power supply to the pump until work is
completed.
WARNING
The pump casing and exhaust piping become extremely hot during
operation and for some time after stopping.
Keep pump and exhaust piping away from contact with personnel and
flammable substances.
Do not remove the pump cover during operation.
WARNING
Check for gas leaks after installing and maintaining the piping.
Gas leaks will result in the discharge of harmful and dangerous
substances and in abnormal reactions due to the admission of air into
the pump.
EBARA
Corporation
Содержание A07V
Страница 9: ...vii EBARA Corporation...
Страница 10: ...viii EBARA Corporation...
Страница 11: ...ix EBARA Corporation...
Страница 14: ...xii Blank page EBARA Corporation...
Страница 21: ...7 EBARA Corporation Outline Drawing A70W...
Страница 22: ...8 Outline Drawing A30W EBARA Corporation...
Страница 23: ...9 EBARA Corporation Outline Drawing A25S...
Страница 24: ...10 EBARA Corporation Outline Drawing A10S...
Страница 25: ...11 EBARA Corporation Outline Drawing A07V...
Страница 60: ...46 Blank Page EBARA Corporation...
Страница 63: ...III Label Country US Label Emergency Number 716 293 3330 EBARA Corporation...
Страница 69: ...IX Blank Page EBARA Corporation...