11
11. DISPOSAL
This product falls within the scope of Directive 2012/19/EU regarding the
management of electrical and electronic equipment waste (WEEE).
Electronic-electrical equipment must not be disposed of with domestic waste
as it is made of various materials that can be recycled at the appropriate
facilities. Inquiries should be made through the municipal authorities regarding
the location of the ecological platforms that receive products for disposal and
their subsequent correct recycling.
Furthermore, it is worth remembering that, upon purchase of an equivalent
appliance, shops are obliged to collect the product for disposal free of charge.
This product is not potentially dangerous for human health and the environ-
ment, since it does not contain harmful substances as per Directive 2011/65/
EU (RoHS), yet if abandoned in the environment it has a negative impact
on the ecosystem.
Read the instructions carefully before using the appliance for the first time. It is
recommended that you do not use this product for any purpose other than that
for which it was intended; there is danger of electric shock if used improperly.
The crossed-out bin symbol found on the appliance label indicates the com-
pliance of this product with the regulations regarding electrical
and electronic equipment waste.
Abandoning the appliance in the environment or its illegal disposal is pun-
ishable by law. Specific cases are, however, indicated in the “DISPOSAL”
chapter in PART 2.
This symbol on the pump means that it cannot be disposed of with household waste.
According to Article 9(1)(i) of the Waste Framework Directive 2008/98/EC and
to the 1907/2006 REACH regulation, all EBARA products have been notified
to the European Chemicals Agency (ECHA).
To consult the SCIP Number with related information on the safe use of the product
see section “Company Certifications” on the website www.ebaraeurope.com
12. SUPPLIED TECHNICAL DOCUMENTATION
12.1. DRAWING SHOWING THE ELECTRICAL CONNECTIONS OF A
SINGLE PHASE MOTOR-DRIVEN PUMP
See FIG. 1-2
12.2. DRAWINGS SHOWING THE ELECTRICAL CONNECTIONS OF A
THREEPHASE PUMP
See FIG. 3-4-5
12.3. EXAMPLE OF A PLATE
See FIG. 6.1-6.2 (The manufacturer reserves the right to modify it).
EN
FIG. 3
FIG. 4
FIG. 5
FIG. 1
FIG. 2
DISPLAYED FAULT
CAUSE
SOLUTION
THE PUMP DOES
NOT STOP
Pressure applications
Maximum
pressure too high
Set maximum
pressure at a
lower value
THE PUMP
VIBRATES
Or is too noisy du-
ring operation
Flow rate too high
Reduce the flow rate
Cavitation
Contact the nearest
retailer
Irregular piping
Fix in a better way
Noisy bearing
Contact the nearest
retailer
Foreign bodies sliding
along the motor fan
Remove the foreign
bodies
Incorrect priming
Bleed the pump and/or
fill it again
Содержание 2CDX