Do not install this product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Subject to direct water spray from hoses.
• Ambient temperatures higher than 40°C & lower
than -10°C.
• Possible obstructions that may hinder access to
or removal of the unit.
Warnings & Safety Information
-
All wiring must be in accordance with the current IEE wiring regulations BS7671, or appropriate standards of
your country. Installation should be inspected and tested by a suitably qualified person after completion.
-
Ensure the mains supply (voltage, frequency and phase) complies with the rating label.
-
The unit should be provided with a switched local double pole fused spur fitted with a 3A fuse having a
contact separation of at least 3mm.
-
These units must be earthed.
-
Precautions must be taken to avoid the back-flow of gases into the building from the open flue of gas or other
fuel-burning appliances.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
-
Young children should be supervised to ensure that they do not play with the appliance.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
Ensure that the unit is switched off from supply mains before removing the front cover and service.
-
The installer is responsible for the installation and electrical connection of the unit on site. It is the responsibility
of the installer to ensure that the equipment is safely and securely installed and left only when mechanically
and electrically safe.
-
All regulations and requirements must be strictly followed to prevent hazards to life and property, both during
and after installation, and during any subsequent servicing and maintenance.
-
The unit’s condensate drain must be connected to the building’s wastewater drainage system.
-
Certain applications may require the installation of sound attenuation to achieve the sound levels required.
-
The unit must not be connected directly to a tumble drier.
-
The supply and exhaust valves must be fully opened prior to commissioning.
-
The intake air must be drawn from the exterior of the property.
-
The unit should be allowed to stabilise during commissioning for a minimum period of 5 minutes when changing
between boost and normal speeds.
-
Ensure that the unit’s external grilles are a minimum of 1500 mm apart. The exhaust grille should be located at
least 600 mm away from any flue outlet. The inlet grille should be located 2000mm away from any flue outlet.
-
This product and associated duct installation should be carried out in accordance with the Domestic Ventilation
Compliance Guide.
-
The appliance is not suitable to be installed to the exterior of the dwelling.
UK Building Regulations (Part F) Declaration of Conformance
The unit conforms to the 2010 Building Regulation (Part F - Means of Ventilation, F1(1), F(2)) requirements
for fixed systems for mechanical extract fans when installed in accordance with the instructions in this
document and the Domestic Ventilation Compliance Guide.