1.0  General

yHH30B Series Explosion-proof Fixed Camera Station is 

manufactured according to EN IEC60079-0:2018, EN60079-1:2014, 

EN60079-28:2015, EN60079-31:2014. It is used in the hazardous 

areas which are classified as Zone 1 and Zone 2, Group IIA, Group 

IIB and Group IIC gases, temperature group T1~T6, Zone 21 

and Zone 22, containing a combustible dust atmosphere or the 

combination of either. The product has the characteristics of small 

volume, light weight, and ease of installation. It can be used in 

petroleum, chemical, jetty, port, mine, spaceflight, war industry 

and foodstuff process area.
All associate technical document, drawings and samples of 

yHH30B Series Explosion-proof Fixed Camera Station(hereinafter 

referenced as camera) are tested and certified by DNV, the 

certification numbers are Presafe 19 ATEX 15006X, IECEx PRE 

19.0070X. 

Specifc Conditions of Use

• 

Repairs of the flameproof joints must be made in compliance 

with the structural specifications provided by the manufacturer. 

Repairs must not be made on the basis of values specified in 

tables 3 and 4 of EN 60079-1.

• 

The mechanical property class of the fasteners which are 

relevant to the flameproof joint should be at least A4-70 with 

min. yield stress 450Mpa. 

• 

Before application, separate ATEX certified EX db IIC Gb or/

and Ex tb IIIC Db IP66/IP68 cable gland should be incorporated. 

Unused entries must be closed by suitable ATEX or IECEx 

certified blank plugs.

• 

Before application, the optical fibre must be connected and 

protected according to the guidance in the instruction manual to 

meet the requirements of IEC 60079-28.

Essential Health and Safety Requirements

Essential Health and Safety Requirements (EHSRs) are covered by 

the standards listed at item 9.

2.0 Technical data

2.1  Type and model

Second stage

Design code

Ex product code,  H stand for  

protective shield

Company code

YH  H  30 

2.2  Certification

Ex marking:  

 

 

II 

2G  Ex db 

II

C T5 Gb (normal version) or Ex db 

op pr IIC T5 Gb  

(optical fiber version)

  

 

 

II 

2D  Ex tb 

III

C T95°C Db (normal version) or Ex 

tb op pr 

III

C T95°C Db  

(optical fiber version)

Cer. number: Presafe 19 ATEX 15006X, IECEx PRE 19.0070X

2.3  Model

YHH30B

Ex camera set, Wiper can be installed according to 

customer reqvuirements

2.4  Electrical data

Input voltage

110~240V a.c. / 24V a.c. 50Hz/60Hz

Input Voltage floating 

range

±10%

Current

0.2~0.45A /≤2A

POE Input voltage

DC54V, ≤1A

Power supply of the 

camera

12VDC (provided by internal device)

Consumption

≤50W 

Network video signal 

output

Output via CAT5e
Output via fiber
Output via coaxial cable (EOC)

Electrical connection

three-core cable is used for power supply, CAT5e cable is 

used for camera control and Network signal output

2.5  Mechanical data

Material: 

stainless steel 316L

IP code

IP66

IPX8 (1.2M/45min) (The equipment has been 

separately tested against the requirements of  

IEC 60529)

External dimension

487.5(L) x 202(H) x 172.5(W) mm

Observation 

port

Thickness

15mm

Exposed area

Φ

68mm

Weight/ Hauled weight

15Kg / 27.5Kg

Numbers of cable entries

3

Thread spec of the cable entries

M25×1.5

Installation method

Electrical platform, semi-fixed platform,  

fixed support

2.6  Service condition

Atmospheric pressure

80~110KPa

Ambient temperature

-40

°C

~+65

°C

Relative humidity

95%RH(+25

°C

)

Содержание YHH30B Series

Страница 1: ...era Station Ex Marking II 2G Ex db II C T5 Gb normal version or Ex db op pr IIC T5 Gb optical fiber version II D Ex tb IIIC T95 C Db normal version or Ex tb op pr IIIC T95 C Db optical fiber version Certificate numbers Presafe 19 ATEX 15006X IECEx PRE 19 0070X ...

Страница 2: ...e definition Connect the cables according to the requirement indicated in the Instruction Manual or fault may occur Protect the flame proof joint in maintenance avoid any metal fragment or other abrasive substances getting inside the internal chamber No disassembly or modification allowed 2 Environmental protection Components of the products made by our company may pollute the environment such as ...

Страница 3: ...3 Fiber optic cable processing 8 3 4 Installation of protective shield and cylinder 8 3 5 System connection 8 3 6 Install camera to platform 9 3 7 Install camera to fixed support 9 3 8 Flame proof joint protection 9 3 9 Grounding 9 3 10 Camera Time settings 9 4 0 Ex structure instruction 9 5 0 Troubleshooting 10 6 0 Transportation and storage 10 7 0 Mounting accessories 11 8 0 Quality guarantee 13...

Страница 4: ...n the optical fibre must be connected and protected according to the guidance in the instruction manual to meet the requirements of IEC 60079 28 Essential Health and Safety Requirements Essential Health and Safety Requirements EHSRs are covered by the standards listed at item 9 2 0 Technical data 2 1 Type and model Second stage Design code Ex product code H stand for protective shield Company code...

Страница 5: ...ension Figure 1 External dimensions of YHH30B 2 8 Installation size Figure 2 Fixing holes at the bottom of the camera 2 9 Wiring The product has the following wiring methods please select one of the wiring methods according to the purchased specifications AC24V or AC220V input Network video signal network cable output ...

Страница 6: ... instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com AC24V or AC220V input Network video signal coaxial cable output AC24V or AC220V input Network video signal fiber output ...

Страница 7: ...7 Installation instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com Power Over Ethernet ...

Страница 8: ...above 90 C 3 3 Fiber optic cable processing This product does not provide an output cable Users using the optical signal output version please weld the incoming fiber and the fiber jumper provided by our company with a fiber fusion splicer The welding place needs to be protected by a fiber protection tube and placed in the fiber protection bracket As shown below Figure 3 The insulation fiber remov...

Страница 9: ...he flame proof joint in installation operation maintenance of this product no knock or scratch allowed 3 9 Grounding Internal and external grounding shall be well connected and reliable 3 10 Camera Time settings During product use the camera needs to reset the time after each power outage restart 4 0 Ex structure instruction The maximum surface temperature will no more than 80 C in normal operatio...

Страница 10: ...of power supply check the power supply self handle open circuit of signal wire check the signal wire self handle damaged camera replace the camera contact the manufacturer damaged lenses replace the lenses contact the manufacturer 6 0 Transportation and storage The packaged product can be delivered in all modes of transportation but without exposure to direct rain or snow it can be stored for one ...

Страница 11: ...11 Installation instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com 7 0 Mounting accessories Mounting accessories order needed Figure 7 YHZ B20 support ...

Страница 12: ... Installation instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com Platform top view Platform side view Platform bottom view Figure 8 YHZ F1 semi fixed platform ...

Страница 13: ...y Thunder or other force majeure natural disasters If any other contracts between clients and us exist we will follow the promise or regulation strictly 9 0 Company statements Cooper Yuhua Changzhou Electric Equipment Manufacturing Co Ltd reserves the right to the interpretation of the modification of product design and specification without notice This Instruction Manual is Cooper Yuhua Changzhou...

Страница 14: ... package of drying agent is provided with accessories Put the drying agent inside the chamber after it s well installed and wired The place of drying agent put shall be away from the transmission element or electrical connection zone and difficult to slip to other places avoid any connection fault or transmission fault caused by drying agent ...

Страница 15: ...the content of the poisonous harmful substances or elements in the component homogeneous material is lower than the limit specified in the standard 2 Symbol means the content of the poisonous harmful substances or elements in the component some certain homogeneous material is more than the limit specified in the standard SJ T11363 2006 Leakage or mutation of this poisonous harmful substances or el...

Страница 16: ...based on the similarities and dissimilarities between product offerings It is not intended to replace specific product literature for Eaton products Information contained in this literature about other manufacturers product is from written material and or published or made available by the manufacturers CONFIDENTIAL For internal use only by Eaton and authorized distributors This information is int...

Отзывы: