29 Analog weigh module XN-322-2DMS-WM
29.8 Memory layout
232
XN300 slice modules
06/16 MN050002 EN
www.eaton.com
29.8 Memory layout
CAN
Object
Index
Size
(byte)
Description
Bit
0x3060
2
Modules Diagnostics
(Error bits 7 and 8 will be set to "zero"
the moment the set gain matches the
stored values. The application must
ensure that the correct GAIN (and
filter type and filter depth) is set. If
the gain changes, the calibration
must be repeated.)
Bit 0
reserved
Bit 1
no SYNC signal
Bit 2
FLASH-CRC error
Bit 3
RAM-CRC error
Bit 4
FLASH memory error
Bit 5
Bridge 1 DC not OK
Bit 6
Bridge 2 DC not OK
Bit 7
Offset ADC 1 invalid
Bit 8
Offset ADC 2 invalid
Bit 9
Filter ADC 1 not ready
Bit 10
Filter ADC 2 not ready
Bit 11…15
reserved
0x3061
4
Measured value 1 (AI1)
Current value of channel (if
AI1ConfigValid and the Ready bit in
AI1ADCState are set)
Measured value 1 (AI1) DWORD
0x3062
4
Measured value 2 (AI2)
Current value of channel (if
AI2ConfigValid and the Ready bit in
AI2ADCState are set)
Measured value 2 (AI2) DWORD
0x3063
2
Diagnostic ADC Controller
Byte 0
ADC AI1
Bit 0…4
reserved
Bit 5
Faulty reference voltage
Bit 6
ADC measuring range error
Bit 7
Conversion in progress
1 Byte
ADC AI2
Bit 0…4
reserved
Bit 5
Faulty reference voltage
Bit 6
ADC measuring range error
Bit 7
Conversion in progress