XFG1 HD IP Fixed Optical Camera Station
XFG1 HD IP OPtIcal FIXeD camera
TMOX001.A September 2021 www.eaton.com
5.0 CERTIFICATION / LABELLING &
MARKING
The certifi cation & rating labels are etched on 316 stainless
steel and fi xed to the units using stainless steel rivets. The
contents of the label will be in ENGLISH.
The label shows:
A - Name of Manufacturer
B – Model Type
C - Operating Voltage
D - EX ratings,
E - ATEX Certifi cate & IECEX certifi cate numbers
F - Serial Number,
G - Notifi ed Body Number
ATEX/IECEx Enclosure Label
CODING
IECEx & ATEX
II 2 G Ex db *IIB *T4 Gb -##°C ≤ Ta ≤ +##°C
II 2 D Ex tb IIIC T135°C Db IP66/67
*=T class, Gas Group
Note: T class, is dependent on the maximum specifi ed
operating temperature
## = Ambient Temperature range. Marked Ambient range
can be any of the following: -55°C to +40°C, -55°C to +55°C,
-55°C to +85°C
6.0 INSTALLATION
It is not anticipated that entry into the fl ame proof enclosure
will be required by the user as power and transmission cables
are supplied pre-installed with the unit. However, when
opening the unit for any reason, follow the steps below.
WARNING: DO NOT OPEN WHEN ENERGISED OR WHEN
AN
EXPLOSIVE ATMOSPHERE IS PRESENT. CLEAN WITH
DAMP CLOTH
1. Cable termination should be in accordance with
specifi cations applying to the application.
2. MEDC recommend that all cables and cores should be fully
identifi ed.
3. Ensure that only the correct certifi ed glands are used, and
that the assembly is shrouded and correctly earthed
4. Ensure there is not too much slack of cable cores within the
unit, due to space limitations.
5. Ensure that only the correct certifi ed stopping plugs are
used to blank any unused gland entry points. We recommend
the use of ‘HYLOMAR PL32 COMPOUND’ on the threads of
stopping plugs in order to maintain the IP66/67 rating of the
unit.
6. Unscrew the grub screw on the Lens cover assembly one
full turn (2.0mm A/F hexagon key required).
7. Unscrew and remove the cover. Once the cover has been
removed, slide the camera from the enclosure.
8. To replace the cover, use the same procedure as above but
in reverse manner, ensuring the cover is screwed tightly. There
should be a maximum gap of 0.2mm between the faces of the
enclosure and cover to ensure 0-ring compression.