A Ex ANNEX – Controlled ATEX Document

Title: 

Series XFG1 flame proof cameras. Installation & Maintenance Instructions

Document: 

 

XFG1 CAMERA

Revision:   1.0

Date: 

  29/04/2021

This is a certified Annex and must not be changed without authorization

SPECIFIC CONDITIONS FOR SAFE USE

1.  No modification must be made to the flame paths of the unit without consultation to the drawings listed on the 

schedule.

2.  Cable Temperature rise at the branching point may be 30K, suitably rated cable must be used.

3.  When fitted, the optical fibre output from the camera must always be terminated within a suitably certified 

enclosure or safe area.

4.  Only armoured cable or conduit is to be utilized when fitted with a fibre optic output in order to protect the fibre 

optic cable.

5.  Precautions must be taken to avoid dust from forming layers on the equipment.

6.  Painting and surface finishes, other than those applied by the manufacturer, are not permitted.

7.  Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof 

cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be 

fitted with certified flameproof stopping plugs. The cable entry devices, thread adapters and stopping plugs shall 

be suitable for the equipment, the cable and the conditions of use and shall be certified as Ex Equipment and not 

an Ex Component. When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress 

protection of the enclosure.

8.  When an adapter is used with an increased safety, dust protected, or a flameproof enclosure for which an IP 

rating is specified, the interface between the enclosure and the adapter and that between the adapter and the cable 

entry device shall be suitably sealed in accordance with IEC 60079-14 so as to maintain the ingress protection rating 

of the enclosure

9.  To prevent the build-up of Electrostatic charge the unit should only be cleaned with a damp cloth.

10.  The Sunshield is an integral part of the unit containing the certification label and must not be removed.

Содержание XFG1 HD IP

Страница 1: ...XFG1 HD IP Fixed Optical Camera Oxalis XFG1 HD IP Fixed Optical Camera Technical Manual...

Страница 2: ...ARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOC...

Страница 3: ...Table of Contents 1 0 INTRODUCTION 4 2 0 GENERAL SAFETY MESSAGES AND WARNINGS 4 3 0 GENERAL ARRANGEMENT 5 4 0 ELECTRICAL INSTALLATION 6 5 0 CERTIFICATION LABELLING MARKING 7 6 0 INSTALLATION 7 7 0 MAI...

Страница 4: ...on installation and operation should be referred to e g IEE Wiring Regulations and the National Electrical Code in North America Additional national and or local requirements may also apply vii Cable...

Страница 5: ...5 XFG1 HD IP Fixed Optical Camera Station XFG1 HD IP OPtIcal FIXeD camera TMOX001 A September 2021 www eaton com Fig 1 Tilt Swivel bracket 3 0 GENERAL ARRANGEMENT...

Страница 6: ...local national codes of practice and standards e g EN 60079 14 2014 and IEC 60079 14 2013 Due to the large number of possible configurations this manual only covers the standard installation of the un...

Страница 7: ...when opening the unit for any reason follow the steps below WARNING DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT CLEAN WITH DAMP CLOTH 1 Cable termination should be in accord...

Страница 8: ...it is exposed to regularly extreme weather conditions the O ring weather seal in the removable window is replaced every five years If the cover lens assembly grease needs to be re applied a PFPE Perfl...

Страница 9: ...lied by the manufacturer are not permitted 7 Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices with or without the interposi...

Страница 10: ...anges to the products to the information contained in this document and to prices are reserved so are errors and omissions Only order confirmations and technical documentation by Eaton is binding Phot...

Отзывы: