sure on the devices or strain on connection wires).
xComfort devices MUST NOT be changed, neither in technical, mechanical and/or electrical
terms. Exception: Shortening of connection wires.
Devices must not be opened.
xComfort devices must be and stay accessible for programming, replacement and mainte-
nance purposes (i.e. NO wall-paper on distribution boxes, NO immuring etc).
Torques for screw-type terminals on the device need to be respected! For terminals from
third-party suppliers (e.g. lustre terminals) you need to respect the manufacturers' technical
data.
Once the job has been done, all the installation boxes need to be closed again. All live com-
ponents need to be touch-proof.
Installation boxes and distributors must be flame-retardant in compliance with the respective
rules and regulations.
Neutral conductor displacements in the system network used are NOT allowed and can
destroy/damage the devices.
Phase and neutral conductor need to be correctly connected.
Protective earth PE needs to be provided where required by terminal equipment (e.g. lamp
with a metal housing).
After removing any xComfort actuators, the incoming capacitor of the actuators needs to be
discharged (risk of electric shock).
Connecting the sensors and loads or consumers has to be done in accordance with the
technical section of our catalogue or with the mounting instructions supplied with each pro-
duct. All technical data and recommendations need to be respected.
Any connection wires not used must be touch-proof.
Country-specific waste disposal and environmental regulations (e.g. for defective devices,
batteries, …) need to be respected.
Applications:
xComfort products MUST NOT be used for safety installations and safety-relevant functions,
especially for:
Safety temperature switches and limiting equipment of heating systems
Final position detection and switch-off or safety functions related to the influence of the
weather on shading systems (wind,rain,hail ...)
Safety and EMERGENCY STOP functions in general
Conventional fire alarm systems