Installation Dimensions in mm (inches)

P

A

B

P

A

B

10

63,5 (2.5)

60,0 (2.36)

67 (2.34)

46,5

(1.83)

0

Ø 9
(0.354 dia)

Ø 5,5 (0.217 dia)

3,0
(0.12)

Mounting surface,
seals supplied with
valve.

Ø 3,0
(0.118 dia)

3,0 (0.12)

52,0

(2.05)

58,0

(2.28)

94,0

(3.7)

117,5 (4.62)
Models with
key lock

137,5 (5.4)
To remove key

7,0 (0.28)

7,5 (0.3)

To adjust controlled flow rate:
For valves with key lock, first unlock by
turning key counter-clockwise. Turn
adjustment knob clockwise to increase flow
rate, or counter-clockwise to decrease flow
rate. Relock models with key lock.

A

B

FCG-3 models only

3rd angle
projection

For dimensions of ISO 4401, size 03 mounting surface and
Vickers subplates, see catalog 2425.
For details of Vickers fixing bolt kits, see catalog 2314.

Note the following exceptions to the standard interface:
1. Only two fixing bolt holes are required, as shown above.
2. Port T is never required.
3. Port P is used only for FCG-3-***-A models.

4

Mass

All models

1,1 kg (2.4 lb) approx.

. . . . . . 

Installation Data

Mounting Attitude
Unrestricted

Mounting Surface, Subplates and
Fixing Bolts
See note in “Installation Dimensions”
section. F(C)G-3 valves cannot be used
to top normal ISO 4401 size 03/NFPA
D01 module stacks unless the
application will be satisfactory with a
two-bolt fixing and with the two or
three-port arrangements of the F(C)G-3
valves; consult your Vickers

representative if such an arrangement 
is required.

A two-bolt fixing kit BK 986743M
containing M5 x 60 long soc. hd. cap
screws is available separately for
securing an F(C)G-3 valve direct to a
subplate.

Ordering Procedure

Valves and fixing bolt kits must be
ordered as separate items e.g.
2 off FCG-3-120-A-K-10 valve
2 off BK 986743M bolt kit

Service and Repair

The construction of these valves is such
that the only spare parts available are
the mounting surface seals (kit no.
986742 containing three seals).
Experience shows that the only
servicing likely to be needed is the
possibility to dismantle the
spring-loaded hydrostat for cleaning in
cases where contaminant has
accumulated through continuous use in
less than ideal environments. For details
see “Spare Parts” leaflet 40594.

Содержание Vickers FG-3 10 Series

Страница 1: ...s are designed to provide adjustable controlled flow rates independent of changes in inlet and or outlet pressures above a minimum pressure differential Models are available with or without integral reverse flow check valves Those with check valves are optionally available with an anti jump feature designed to eliminate transient surges above the controlled flow rate setting whenever flow is first...

Страница 2: ...6 32 models F C G 3 63 120 180 models 5 bar 75 psi 8 5 bar 125 psi Flow Limits Recommended controlled flow ranges F C G 3 10 F C G 3 16 F C G 3 32 F C G 3 63 F C G 3 120 F C G 3 180 0 015 to 1 0 L min 0 004 to 0 26 USgpm 0 015 to 1 6 L min 0 004 to 0 42 USgpm 0 025 to 3 2 L min 0 007 to 0 85 USgpm 0 025 to 6 3 L min 0 007 to 1 66 USgpm 0 08 to 12 0 L min 0 02 to 3 17 USgpm 0 08 to 18 0 L min 0 02 ...

Страница 3: ...ant fluids are required to be used consult your Vickers representative The extreme operating viscosity range is from 300 to 10 cSt 1460 to 54 SUS but the recommended running range is from 54 to 13 cSt 245 to 70 SUS For further information fluids see catalog 920 Temperature Limits Min 20_C 4_F Max 80_C 176_F To obtain optimum service life from both fluid and hydraulic system 65_C 150_F is normally ...

Страница 4: ...ation Data Mounting Attitude Unrestricted Mounting Surface Subplates and Fixing Bolts See note in Installation Dimensions section F C G 3 valves cannot be used to top normal ISO 4401 size 03 NFPA D01 module stacks unless the application will be satisfactory with a two bolt fixing and with the two or three port arrangements of the F C G 3 valves consult your Vickers representative if such an arrang...

Отзывы: