background image

Typical with petroleum oil at 36 cSt (170 SUS) and at 50

_

C (122

_

F)

Controlled Flow, F(C)G-3-16/32 Models

0

1

2

3

4

5

6

7

8

9

10

Scale reading

0

4,0

3,6

3,2

2,8

2,4

2,0

1,6

1,2

0,8

0,4

1.0

0.2

0.4

0.6

0.8

Flow rate

USgpm

L/min

27 54 81 108 135 162 189 216 243 270

0

Angular rotation (degrees) from zero

Controlled Flow, F(C)G-3-63/120/180 Models

0

1

2

3

4

5

6

7

8

9

10

Scale reading

0

Flow rate

USgpm

L/min

27 54 81 108 135 162 189 216 243 270

0

2

4

6

8

10

12

14

16

18

20

4

5

3

2

1

Angular rotation (degrees) from zero

Reverse Flow Pressure Drop, FCG Models

bar

0

psi

Flow rate

Pressure drop

2

4

6

8

100

80

60

40

20

120

0

0

L/min

USgpm

10

12

10

20

30

140

160

1

2

3

4

5

6

7

8

3

Performance Data

Thermal stability of controlled flow,
typical example:
Flow set at 20

_

C (68

_

F)

0,25 L/min

. . . . 

(0.07 USgpm)

Flow increase at
70

_

C (158

_

F)

+12%

. . . . . . . . . . . . . . . . . 

Hydraulic Fluids
All valves can be used with antiwear or
other hydraulic petroleum oils. If
fire-resistant fluids are required to be
used, consult your Vickers
representative. The extreme operating
viscosity range is from 300 to 10 cSt
(1460 to 54 SUS) but the recommended
running range is from 54 to 13 cSt 
(245 to 70 SUS). For further information
fluids see catalog 920.

Temperature Limits
Min.

–20

_

C (–4

_

F)

. . . . . . . . . . . . . . . . . . 

Max.*

+80

_

C (176

_

F)

. . . . . . . . . . . . . . . . 

*  

To obtain optimum service life from both

fluid and hydraulic system, 65

_

C (150

_

F) is

normally the maximum temperature for
hydraulic petroleum oils.

Whatever the actual temperature range,
ensure that the viscosities stay within
the limits specified in the “Hydraulic
Fluids” section.

Contamination Control Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, “Vickers Guide to Systemic
Contamination Control”. The book also
includes information on the Vickers
concept of “ProActive Maintenance”.
The following recommendations are
based on ISO cleanliness levels at 

m

m, 5 

m

m and 15 

m

m. For products in

this catalog the recommended levels are:

Up to 210 bar (3050 psi)

19/17/14

. . . . . 

Above 210 bar (3050 psi)

19/17/14

. . . . 

Содержание Vickers FG-3 10 Series

Страница 1: ...s are designed to provide adjustable controlled flow rates independent of changes in inlet and or outlet pressures above a minimum pressure differential Models are available with or without integral reverse flow check valves Those with check valves are optionally available with an anti jump feature designed to eliminate transient surges above the controlled flow rate setting whenever flow is first...

Страница 2: ...6 32 models F C G 3 63 120 180 models 5 bar 75 psi 8 5 bar 125 psi Flow Limits Recommended controlled flow ranges F C G 3 10 F C G 3 16 F C G 3 32 F C G 3 63 F C G 3 120 F C G 3 180 0 015 to 1 0 L min 0 004 to 0 26 USgpm 0 015 to 1 6 L min 0 004 to 0 42 USgpm 0 025 to 3 2 L min 0 007 to 0 85 USgpm 0 025 to 6 3 L min 0 007 to 1 66 USgpm 0 08 to 12 0 L min 0 02 to 3 17 USgpm 0 08 to 18 0 L min 0 02 ...

Страница 3: ...ant fluids are required to be used consult your Vickers representative The extreme operating viscosity range is from 300 to 10 cSt 1460 to 54 SUS but the recommended running range is from 54 to 13 cSt 245 to 70 SUS For further information fluids see catalog 920 Temperature Limits Min 20_C 4_F Max 80_C 176_F To obtain optimum service life from both fluid and hydraulic system 65_C 150_F is normally ...

Страница 4: ...ation Data Mounting Attitude Unrestricted Mounting Surface Subplates and Fixing Bolts See note in Installation Dimensions section F C G 3 valves cannot be used to top normal ISO 4401 size 03 NFPA D01 module stacks unless the application will be satisfactory with a two bolt fixing and with the two or three port arrangements of the F C G 3 valves consult your Vickers representative if such an arrang...

Отзывы: