Model Code
F(C)G
Type
FCG =
Flow control with reverse flow
check
FG =
Flow control without reverse
flow check
Max. controlled flow rate
10 =
1,0 L/min (0.26 USgpm)
16 =
1,6 L/min (0.42 USgpm)
32 =
3,2 L/min (0.85 USgpm)
63 =
6,3 L/min (1.66 USgpm)
120 =
12,0 L/min (3.17 USgpm)
180 =
18,0 L/min (4.75 USgpm)
-3- *** (-A) - *
1
2
4
5
1
2
3
- 10
Anti-jump feature (FCG model
option)
Omit when not required and for all FG
models.
Controlled flow adjustment
H = Manual without key lock
K = Manual with key lock
Design number, 10 series
Subject to change. Installation
dimensions remain unchanged for
design numbers 10-19 inclusive.
5
3
4
2
Operating Data
Pressure Limits
Max. pressure, all ports:
FCG-3-***-A models
All other models
160 bar (2320 psi)
315 bar (4500 psi)
Min. pressure differential for effective controlled flow
(port A pressure > port B pressure):
F(C)G-3-10/16/32 models
F(C)G-3- 63/120/180 models
5 bar (75 psi)
8,5 bar (125 psi)
Flow Limits
Recommended controlled flow ranges:
F(C)G-3-10
F(C)G-3-16
F(C)G-3-32
F(C)G-3-63
F(C)G-3-120
F(C)G-3-180
0,015 to 1,0 L/min (0.004 to 0.26 USgpm)
0,015 to 1,6 L/min (0.004 to 0.42 USgpm)
0,025 to 3,2 L/min (0.007 to 0.85 USgpm)
0,025 to 6,3 L/min ( 0.007 to 1.66 USgpm)
0,08 to 12,0 L/min (0.02 to 3.17 USgpm)
0,08 to 18,0 L/min (0.02 to 4.75 USgpm)
Max. recommended reverse flow (FCG model)
30 L/min (7.9 USgpm)
Applications
FG-3 models are for general use in
meter-in, meter-out or bleed-off
applications.
FCG-3-***-*-10 models are for general use
in meter-in or meter-out applications in
which high reverse flow rates can occur.
FCG-3-***-A-10 models are for similar
use in those meter-in applications where
the possibility of transient surges above
the controlled flow rate setting,
whenever flow is first directed to the inlet
port, is undesirable, e.g.
– for feed speed control
– for successive fast approach/feed
sequences (fine machining of
interrupted bores).