background image

Model Code

F(C)G

Type

FCG =

Flow control with reverse flow 
check

FG =

Flow control without reverse 
flow check

Max. controlled flow rate

10 =

1,0 L/min (0.26 USgpm)

16 =

1,6 L/min (0.42 USgpm)

32 =

3,2 L/min (0.85 USgpm)

63 =

6,3 L/min (1.66 USgpm)

120 =

12,0 L/min (3.17 USgpm)

180 =

18,0 L/min (4.75 USgpm)

-3- *** (-A) - *

1

2

4

5

1

2

3

- 10

Anti-jump feature (FCG model
option)

Omit when not required and for all FG
models.

Controlled flow adjustment

H = Manual without key lock
K = Manual with key lock

Design number, 10 series

Subject to change. Installation
dimensions remain unchanged for
design numbers 10-19 inclusive.

5

3

4

2

Operating Data

Pressure Limits

Max. pressure, all ports:

FCG-3-***-A models
All other models

160 bar (2320 psi)
315 bar (4500 psi)

Min. pressure differential for effective controlled flow 
(port A pressure > port B pressure):

F(C)G-3-10/16/32 models
F(C)G-3- 63/120/180 models

5 bar (75 psi)
8,5 bar (125 psi)

Flow Limits

Recommended controlled flow ranges:

F(C)G-3-10
F(C)G-3-16
F(C)G-3-32
F(C)G-3-63
F(C)G-3-120
F(C)G-3-180

0,015 to 1,0 L/min (0.004 to 0.26 USgpm)
0,015 to 1,6 L/min (0.004 to 0.42 USgpm)
0,025 to 3,2 L/min (0.007 to 0.85 USgpm)
0,025 to 6,3 L/min ( 0.007 to 1.66 USgpm)
0,08 to 12,0 L/min (0.02 to 3.17 USgpm)
0,08 to 18,0 L/min (0.02 to 4.75 USgpm)

Max. recommended reverse flow (FCG model)

30 L/min (7.9 USgpm)

Applications
FG-3 models are for general use in
meter-in, meter-out or bleed-off
applications.
FCG-3-***-*-10 models are for general use
in meter-in or meter-out applications in
which high reverse flow rates can occur.

FCG-3-***-A-10 models are for similar
use in those meter-in applications where
the possibility of transient surges above
the controlled flow rate setting,
whenever flow is first directed to the inlet
port, is undesirable, e.g.
– for feed speed control
– for successive fast approach/feed 

sequences (fine machining of 
interrupted bores).

Содержание Vickers FG-3 10 Series

Страница 1: ...s are designed to provide adjustable controlled flow rates independent of changes in inlet and or outlet pressures above a minimum pressure differential Models are available with or without integral reverse flow check valves Those with check valves are optionally available with an anti jump feature designed to eliminate transient surges above the controlled flow rate setting whenever flow is first...

Страница 2: ...6 32 models F C G 3 63 120 180 models 5 bar 75 psi 8 5 bar 125 psi Flow Limits Recommended controlled flow ranges F C G 3 10 F C G 3 16 F C G 3 32 F C G 3 63 F C G 3 120 F C G 3 180 0 015 to 1 0 L min 0 004 to 0 26 USgpm 0 015 to 1 6 L min 0 004 to 0 42 USgpm 0 025 to 3 2 L min 0 007 to 0 85 USgpm 0 025 to 6 3 L min 0 007 to 1 66 USgpm 0 08 to 12 0 L min 0 02 to 3 17 USgpm 0 08 to 18 0 L min 0 02 ...

Страница 3: ...ant fluids are required to be used consult your Vickers representative The extreme operating viscosity range is from 300 to 10 cSt 1460 to 54 SUS but the recommended running range is from 54 to 13 cSt 245 to 70 SUS For further information fluids see catalog 920 Temperature Limits Min 20_C 4_F Max 80_C 176_F To obtain optimum service life from both fluid and hydraulic system 65_C 150_F is normally ...

Страница 4: ...ation Data Mounting Attitude Unrestricted Mounting Surface Subplates and Fixing Bolts See note in Installation Dimensions section F C G 3 valves cannot be used to top normal ISO 4401 size 03 NFPA D01 module stacks unless the application will be satisfactory with a two bolt fixing and with the two or three port arrangements of the F C G 3 valves consult your Vickers representative if such an arrang...

Отзывы: