background image

4

Safety information

EATON TFX INSTALLATION AND OPERATION MANUAL

   6046279-001   

September 2019

   www.eaton.com

2.0  Safety information

This chapter contains important information on how to avoid 

life-threatening situations and injuries and how to prevent 

product damage.

2.1  Safety instructions

!

  DANGER

Failure of safety-related functions due to deficient 

data transmission.

Severe injury or death.

The device operates using radio signals and is not 

authorized for use in safety-related applications. Insufficient 

mobile network availability, interference or malfunctions of 

the device can cause faulty data transmission. Because of 

this, data transmission can not be guaranteed at all times 

and under all conditions.

 

Never operate this device in machines or applications 

where life depends on the fault-free operation of 

this device.

 

Never rely solely on wireless devices for 

essential communications.

 

The device is designed to be used in systems which 

must be checked for conformity with the respective valid 

legal requirements prior to putting into operation. The 

integrator of the device is responsible for ensuring that 

the final system complies with all regional regulations 

and requirements.

!

  DANGER

Failure of communications systems in aircraft due to radio-

frequency energy.

Severe injury or death.

 

Disconnect the power supply to the device before 

entering the aircraft.

 

Make sure the device cannot be switched on inside 

the aircraft.

 

Note the information in chapter Power management.

!

  DANGER

Danger of explosion due to the operation of electrical 

equipment in potentially explosive atmospheres.

Severe injury or death.

 

Observe the applicable regulations and precautions for 

potentially explosive areas.

 

Do not mount the antenna in the close proximity of easily 

ignited substances (e.g. fuel tanks) and insufficiently 

shielded electronic devices.

!

   WARNING

Danger of interference with medical equipment caused 

by radio frequency (RF) energy.

Severe injury or death.

Medical equipment may be sensitive to RF energy.

The functioning of cardiac pacemakers, other implanted 

medical devices, and hearing aids can be affected if the 

TFX is located too close to the medical devices.

 

Observe the local regulations for use of mobile radio 

devices in hospitals or other medical facilities. Disconnect 

the power supply to the device when local regulations in 

sensitive areas require that you do so.

 

If you use a cardiac pacemaker or other medical device, 

do not come within the close vicinity of the switched-on 

TFX and its antenna.

 

If in doubt about potential danger, contact a physician or 

the manufacturer of the medical equipment to verify that 

it is properly shielded.

!

   WARNING

Danger to life due to electric shock!

Severe injury or death.

 

Never use the device if you suspect damage to the 

power supply unit or the device, or if there is visible 

damage to the power supply unit or the device. 

!

   WARNING

Danger to life due to electric shock!

Severe injury or death.

 

Never carry out repairs to the device yourself. Contact the 

support service. The device does not contain any parts 

that can be repaired or maintained by the user.

!

   WARNING

Overload damage due to malfunction.

Severe injury or death.

 

To limit power in the event of malfunction, secure the DC 

power supply circuit during installation with an external 2 

A fuse.

!

  CAUTION

Health hazards of radio-frequency energy

Slight or medium injury.

 

During operation, observe a distance of at least 20 cm 

between the antennas and personnel.

Содержание TFX Series

Страница 1: ...TFX Installation and Operation Manual...

Страница 2: ...special indirect incidental or consequential damage or loss whatsoever including but not limited to damage or loss of use of equipment plant or power system cost of capital loss of power additional e...

Страница 3: ...non observance Measures to avoid the danger WARNING Nature and source of the danger Consequences of non observance Measures to avoid the danger CAUTION Nature and source of the danger Consequences of...

Страница 4: ...1 4 Conformity 2 1 2 Device functions 2 1 2 1 Available models 2 1 2 2 Scope of supply 3 1 2 3 Kits 3 1 2 4 Software and accessories 3 1 3 Service and support 3 2 0 SAFETY INFORMATION 4 2 1 Safety in...

Страница 5: ...cting the device to the Data platform 18 4 6 Mounting the device 18 5 0 OPERATION 20 5 1 Eaton TFX Configurator 20 5 1 1 Creating object dictionary groups and objects 20 5 2 Logging mode 21 5 2 1 Conf...

Страница 6: ...on 40 5 10 2 OTAP general process 40 5 10 3 OTAP Recovery Mode 41 5 11 Diagnosis via micro USB port 41 5 12 Factory reset 43 5 12 1 Factory reset via OBW file or CAN 43 5 12 2 Factory reset via the st...

Страница 7: ...ATION Not all model variants feature the antenna ports For more information see chapter Available models 1 1 2 Type label The device type label is located on the front of the housing and provides the...

Страница 8: ...open the device housing yourself 1 1 4 Conformity For details of the corresponding approval tests see chapter Certification and qualification The device meets the requirements of the following standa...

Страница 9: ...02EC77300A 102EC77301A Order number for STARTER KIT 102EC77302A 102EC77302A INFORMATION The HARDWARE KIT only includes the TFX and mounting accessories We recommend that customers without an existing...

Страница 10: ...e applicable regulations and precautions for potentially explosive areas Do not mount the antenna in the close proximity of easily ignited substances e g fuel tanks and insufficiently shielded electro...

Страница 11: ...100 MHz UMTS FDD 1 band Changes or modifications to this device not expressly approved by the manufacturer can void the user s authority to operate the device under CE rules INFORMATION The horizontal...

Страница 12: ...ng mode Yes Yes Input output functions Yes Yes Acceleration sensor Yes Yes Gyro sensor Yes Yes CAN connectors 1 1 GNSS Yes Yes eSIM card Yes Yes 3 1 1 Real time mode In real time mode CAN messages are...

Страница 13: ...s an eSIM profile with all the necessary communication settings INFORMATION On delivery the device s eSIM card is not yet enabled After registration of the TFX enabling the eSIM card can take up to 1...

Страница 14: ...prox 3 3 V and can supply active antennas with a maximum of 40 mA of power The port is short circuit resistant and recognizes that an antenna is present from a power greater than approx 2 mA CAUTION H...

Страница 15: ...When several colors are active simultaneously the LEDs also light up in magenta orange or turquoise The following tables show possible LED indications ON LED The ON LED indicates the power supply stat...

Страница 16: ...1 Start cable for main plug connector The cable CLM3 start cable 6 open 2 dsub 1 pw 2 m contained within the Starter Kit features the following connectors and open individual wires 1 micro timer II so...

Страница 17: ...eatures a slide switch for a factory reset INFORMATION For more information on how to perform a factory reset see chapter Factory reset via the start cable D sub connector female 9 pin CAN2 Pin Design...

Страница 18: ...the device is switched on This activates the MCU internal bootloader 3 4 3 USB connector cable diagnosis The USB cable USB A on micro USB B 1 6 m included in Starter Kit is intended for debugging and...

Страница 19: ...malfunction secure the DC power supply circuit with an external 2 A fuse NOTICE Property damage The device must be installed connected and commissioned by a qualified technician Ensure the power suppl...

Страница 20: ...ximity of easily ignited substances e g fuel tanks and insufficiently shielded electronic devices CAUTION Health hazards of radio frequency energy Slight or medium injury Make sure the device is switc...

Страница 21: ...ttention that the USB plug is correctly aligned to the USB port on the computer before being plugged in and that it is plugged in without using excessive force Incorrect alignment during connection or...

Страница 22: ...PC See chapter Connecting the device to the PC 2 Start the EATON Configurator software 3 Click onTools Node Scan in the menu Alternatively you can click on the button in the toolbar 3 3 The Communica...

Страница 23: ...ion file available for your specific device it is recommended to create a new device configuration The required object groups and device variables have to be added manually then Refer to Creating obje...

Страница 24: ...com and check whether the device is connected to the Data platform If your device does not appear in the machine overview you must activate the device See chapter Activation of the device 4 6 Mounting...

Страница 25: ...ositioning 1 Mobile radio antenna 2 GNSS antenna NOTICE Inadequate radio connection The radio connection is influenced by objects or walls Only mount the device in the installation position shown in c...

Страница 26: ...ucture of EATON Configurator you can create rename or delete object dictionary groups or objects This chapter explains how to create object dictionary groups and objects The following example shows cr...

Страница 27: ...you start logging data check the device status in the machine overview in the Portal The device must be in logging mode The colored squares in the machine overview indicate the current status Constan...

Страница 28: ...enable CAN communication and data logging you must configure the following variables CAN VARIABLES The variables required concern the CAN connection and belong to the object dictionary group Device V...

Страница 29: ...ain this 2 In the object dictionary group Receive CAN Messages PDOs create a new object dictionary entry Receive Messages PDO 3 Rename the object Receive Message PDO as pgn 61444 RECEIVE MESSAGE COMMU...

Страница 30: ...ss These are ignored when the message is received 5 2 3 2 Example 1 Log all data bytes every 60 seconds In this example all data bytes are simply logged cyclically every 60 seconds There are no additi...

Страница 31: ...variables belong to the Interface Variables object dictionary group 1 Create the object dictionary group Interface Variables 2 In the INTERFACE VARIABLES object dictionary group create four new Interf...

Страница 32: ...ging in PGN 61444 Payload Description Selection Function Log received CAN message Set Log data of the receive CAN message Bytes to log 2 5 and 8 Logging selected data bytes 5 2 3 3 1 Mapping During ma...

Страница 33: ...e calculation operations have the following functions Buttons Description C clear deletes the entire calculation operation CE clear entry only deletes the last symbol entered Add variables to the calc...

Страница 34: ...le contains position data at least once Enabled Enables disables the position data logging AND OR AND Position data is logged if both conditions time and distance are met OR Position data is logged if...

Страница 35: ...3 3 The Create new Job window opens 12 Select the job type Logging 13 Click on the OK button 3 3 The job is added to the Overview list 14 In the CobID field enter the ID hex for the virtual CAN messag...

Страница 36: ...chine overview indicate the current status Constant blue device is passive in real time mode Flashing blue device is connected to a real time client software Grayed out device is offline Constant gree...

Страница 37: ...transferred to the Data platform you need to take the following steps 1 Check that the object 0x5402 Sub Index 0 has the value 01 This value indicates that PROEMION has transferred a file to the devic...

Страница 38: ...roup contains the following variables Table 32 Device variables I O sensors diagnosis Variable Function Operation time total Device operation time in seconds Device Time Unix Format Internal device ti...

Страница 39: ...Variables Power Management You can enable sleep mode as follows Enabling sleep mode after a set time period Power Management Can Sleep Time Monitoring terminal 15 As soon as the device registers LOW o...

Страница 40: ...end special files to the device via the Data platform to configure or read off variables In the following the files and their structure are described NOTICE Restrictions apply to the file names See ch...

Страница 41: ...ers with administrator rights have this authorization INFORMATION If you do not have authorization to perform a configuration update contact the service support See chapter Service and support 1 Start...

Страница 42: ...0x1018 0x2 ERROR 0x3337 is not equal to 0xTFX Internal Antenna ABORT CONFIGURATION DOWNLOAD ON ERROR newSW Fw 6 1 0 0 Release newBL Bl 9 1 newDOD CANlink mobile 3337 Demo V1 END 1534329798 5 8 2 CAN...

Страница 43: ...the Open button 4 In the Communication Path field select the Connection via Internet n Devices interface from the list 5 Click on the Select Devices button 3 3 The window Select Devices opens 6 If the...

Страница 44: ...w 6 1 0 0 Release newBL Bl 9 2 newDOD FOTA Test V4 END 1532700197 Example of protocol content after a failed update BEGIN 1534330801 actSW Fw 6 1 0 0 Release actBL Bl 9 1 actDOD CANlink mobile 3337 De...

Страница 45: ...evice restarts automatically 3 3 After the restart the device uses the updated firmware version You can find a tutorial on how to install the firmware to the device in the download area of our website...

Страница 46: ...the device uses the updated firmware version You can find a tutorial on how to install the firmware to the device in the download area of our website See also chapter Service and support 5 10 Over the...

Страница 47: ...RMATION Before you connect the device to a USB port on your PC install the USB driver packet from Eaton com TFX See chapter Installing software 1 Connect the device to a PC with the USB A to micro USB...

Страница 48: ...the menu click on CAN Filter Settings Driver optimized settings Totally open for 11 and 29 bit messages 12 Click on the OK button to save the settings 13 Click on Tools Node Scan in the menu Alternat...

Страница 49: ...t to Firmware Defaults Local 0x1011 0x65 The standard configuration of the current firmware is restored All logged data and parameters are deleted The factory configuration is retained INFORMATION You...

Страница 50: ...ng plugged in and that it is plugged in without using excessive force Incorrect alignment during connection or the use of excessive force could cause damage to the USB port 1 Connect the device to a P...

Страница 51: ...the device Do not disconnect the device from the power supply until the process has been completed 3 3 The device reverts to the firmware defaults object 0x1011 0x65 3 3 The ON LED lights up green 3...

Страница 52: ...ration whether the device is in Operational mode Check the logging configuration 6 1 1 Support request If you do not find the solution to your problem in this manual please contact our support service...

Страница 53: ...Device Manage 3 Enter the device name or IMEI number in the search box 4 Click on the Details button of the corresponding device 3 3 The detail view of the selected device is shown 5 In the field Host...

Страница 54: ...hat can be repaired or maintained by the user NOTICE Property damage Any defective device must be inspected and repaired by a trained supplier service technician Do not open the device housing yoursel...

Страница 55: ...ical and Electronic Equipment WEEE the device must not be disposed of in household waste Take the device to a collection point for waste electrical and electronic equipment for correct disposal 9 0 An...

Страница 56: ...quency range Models TFX Internal Antenna TFX External Antenna 2G GSM GPRS Edge 850 900 1800 1900 MHz 3G UMTS HSPA 850 900 1900 2100MHz Mobile radio transmission rate GPRS upload 85 6 kbit s GPRS downl...

Страница 57: ...ge 250 s Resolution 16 bit Sampling rate 10 Hz Tolerance 3 of measurement range end value and offset 3 s at 25 C and 1 g Temperature sensor Measurement range 40 C 85 C 40 F 185 F Resolution 0 1 C Samp...