Electrical Requirements
Electrical
Requirements
SAE J-1939/11 Recommended Cable Termination Procedure
Remove cable outer jacket approximately 25 mm.
Remove foil from exposed wires to within 2 mm from cable jacket.
Strip insulation from data wires 7 mm.
Attach extended wire barrel socket contact to the drain wire or attach adhesive filler solder sleeve and wire to drain wire
per manufacturer’s recommendations.
For the solder sleeve option, cut the wire on the solder sleeve to a length of 25 mm and strip the insulation back 7 mm.
Crimp the appropriate terminal on each data wire and solder sleeve wire or the extended socket per the manufacturer’s
recommendations.
Slide an adhesive filler shrink tube over the cable end.
Install the terminals into the connector body per the manufacturer’s instructions.
Install the wedge in the front of the connector body per the manufacturer’s instructions.
Apply the shrink tube to the end of the connector body per the manufacturer’s recommendation.
Solder Sleeve
with Wire
Extended Socket
Cable
Drain Wire
Shrink Tube
Data Wires
Terminals
Plug
Wedge
Final Assembly
OR