3.5 Powering the PXES6P with 24VDC power input
Each
PXES6P Series is equipped with an internal DC power supply, and has built-in
screw terminals for secure attachment of the power input leads. Where an AC power adaptor is
used, DC is supplied via the jack. Power input from the DC terminal block and the jack and both
may be connected simultaneously for power input redundancy.
33
3.6 continued, DC Power Terminals
: “+”, “-”, gnd
GND
: Terminal for “earth” or ground wire connection to the PXES6P chassis
Input Voltage
:
24VDC
24VDC
(10-36VDC)
(12V or 24V)
(10-30VDC)
Input current
:
0.4 amp max.(24V DC)
34
Power Consumption
: 7 watts typical, 9 watts max.
3.7 PXES6P Series, 24VDC-powered Installation
This section describes the proper connection of the 24VDC leads to the DC power
terminal block on the PXES6P Switch (as shown in the Figure)
.
The DC terminal block on the
PXES6P is located on the left side of the unit and is equipped with three (3) screw-down lead
posts. The power terminals are identified as positive (+) and negative (-), and they are floating
inside the unit so that either of the terminals may be grounded by the user if desired. The chassis
is “earth” or ground (GND). The connection procedure is straightforward. Simply insert the DC
leads to the PXES6P’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) optional; it connects to the PXES6P chassis. Ensure that each lead is securely tightened
from the top, as shown on above picture with arrow.
35