Installing Monitor Pole Top Trim Caps
(Monitor pole top trim caps are not compatible with core walls that are configured with slat wall.)
Attach a top cap support bracket to each end of the core wall’s top channel. Locate the brackets 4 inches from each end of the core
wall section. The hooks on the bracket engage the channel’s vertical flanges. To retain the brackets in place, tighten the (2) Phillips
head clamping screws on each bracket. See figures 41 and 42.
Attach the slotted base plate to the middle of the core wall’s top channel with (6) ¼-20 x ½” hex head self-tapping screws.
(Depending on your configuration, it may be necessary to drill .218” (7/32”) holes into the top channel for the plate mounting
screws.) Then attach the upper pole support to the channel with (4) #10 x 3/4” Phillips head self-tapping screws. See figure 42.
Attach the monitor pole using the hardware and instructions supplied with the pole. Assembly will be similar to figure 43.
Figure 40
Top cap support bracket
Clamping screw
Slotted base plate
Upper pole support
#10 x 3/4” Phillips head
self-tapping screws
4”
¼-20 x ½” hex head
self-tapping screws
Figure 43
Figure 41
Figure 42