23
Profile
Installation Manual
PROFILE INSTALLATION MANUAL
Eaton.com/profile
P a g e
|
21
Eaton’s Profile Command Console
Installation Manual
Stabilizing The Core Wall Structure With An Angular Wedge Upright
Angular wedge uprights assemble to either the concave or convex side of an angular core configuration. They may be used on all
convex angular configurations and all concave angular configurations except 90°. For concave applications, the upright attaches to
the bottom vertical front panel of the angular connector. For convex applications the uprights attach to the vertical core wall
members adjacent to the angular connector. One upright is required for concave applications; two are required for convex
applications.
For concave applications, the rear panel of the angular core connector must be removed to gain access to the transition upright
mounting holes. Re-attach the rear panel after installation of the upright.
First assemble the left and right work surface supports to the transition upright(s) using (4) ¼-20 x ½” Allen head screws and (4) ¼”
lock washers for each support (see figure 21). Then align the upright assembly(s) with the holes in the core wall structure. Attach
the upright(s) with (6) 1/4-20 hex head self-tapping screws (see figures 22 and 23). Adjust the uprights’ leveling feet so that they
contact the floor without influencing the leveling of the core structure.
¼-20 x 1/2” Hex head self-tapping
screws (6)
¼-20 x 1/2” Allen head screws and lock
washers (8)
Work surface supports
Rear panel
Bottom front panel
Figure 21
Figure 22 -Concave Application
Figure 23 – Convex Application
¼-20 x 1/2” Hex head self-tapping screws (3 per
upright)
NOTICE