24
User Manual
MN040024EN
Effective November 2016
DX-NET-ETHERNET2-2 fi eld bus connection
EtherNet/IP for variable frequency drive DE1/DC1
EATON
www.eaton.com
DC1-E parameter mapping
Table 14. Class 0x04 Assembly (Read/write max parameters from Instance)
Drive
Mode
Type
Inst.
Read
service
Max
supported len
Write
service
Max
supported len
Para.
Description
—
Field bus command
R/W
WORD
1
0x18
30
0x19
1
—
Field bus speed reference value 0.1 Hz
R/W
S16
2
0x18
29
0x19
1
—
Reserved R/W
—
3
0x18
28
0x19
1
—
Modbus ramp time
R/W
U16
4
0x18
27
0x19
1
—
—
R
—
5
0x18
26
—
0
—
Status and fault word
R
—
6
0x18
25
—
0
—
Field bus actual speed
R
S16
7
0x18
24
—
0
—
Motor current
R
U16
8
0x18
23
—
0
—
Reserved
R
—
9
0x18
22
—
0
—
Reserved
R
—
10
0x18
21
—
0
—
DI status
R
Binary code
11
0x18
20
—
0
—
Type
R
WORD
12
0x18
19
—
0
—
Power
R
U16
13
0x18
18
—
0
—
Voltage level
R
U16
14
0x18
17
—
0
—
Control section software version
R
WORD
15
0x18
16
—
0
—
Power section software version
R
WORD
16
0x18
15
—
0
—
variable frequency drive recognition
R
WORD
17
0x18
14
—
0
—
Reserved
R
—
18
0x18
13
—
0
—
Reserved
R
—
19
0x18
12
—
0
—
Value AI1
R
U16
20
0x18
11
—
0
—
Value AI2
R
U16
21
0x18
10
—
0
—
Reference input speed
R
S16
22
0x18
9
—
0
—
DC link voltage
R
U16
23
0x18
8
—
0
—
Variable frequency drive temperature
R
S16
24
0x18
7
—
0
—
Variable frequency drive operating time
R
—
25
0x18
6
—
0
—
Variable frequency drive operating time
R
—
26
0x18
5
—
0
—
The variable frequency drive operating time
since the last fault
R
—
27
0x18
4
—
0
—
The variable frequency drive operating time
since the last fault
R
—
28
0x18
3
—
0
—
—
R
—
29
0x18
2
—
0
—
—
R
—
30
0x18
1
—
0
P-01
Maximum frequency / maximum speed
R/W
U16
129
0x18
53
0x19
53
P-02
Minimum frequency / minimum speed
R/W
U16
130
0x18
52
0x19
52
P-03
Acceleration time (acc1)
R/W
U16
131
0x18
51
0x19
51
P-04
Deceleration time (dec1)
R/W
U16
132
0x18
50
0x19
50
P-05
Stop Function
R/W
U16
133
0x18
49
0x19
49
P-06
Energy optimization
R/W
U16
134
0x18
48
0x19
48
P-07
Nominal motor voltage
R/W
U16
135
0x18
47
0x19
47
P-08
Rated motor current
R/W
U16
136
0x18
46
0x19
46
P-09
Rated motor frequency
R/W
U16
137
0x18
45
0x19
45
P-10
Nominal speed of the motor
R/W
U16
138
0x18
44
0x19
44
P-11
Voltage amplification
R/W
U16
139
0x18
43
0x19
43
P-12
Control level
R/W
U16
140
0x18
42
0x19
42
P-13
Fault log history
R/W
U16
141
0x18
41
0x19
41
P-14
Access code (P-15 to P-53
A
101)
R/W
U16
142
0x18
40
0x19
40
P-15
Function of digital inputs
R/W
U16
143
0x18
39
0x19
39
P-16
Analog input 1 (AI1), signal range
R/W
U16
144
0x18
38
0x19
38
P-17
Pulse frequency
R/W
U16
145
0x18
37
0x19
37
P-18
K1 signal (Relay Output 1)
R/W
U16
146
0x18
36
0x19
36
P-19
K1-Limit value (relay)
R/W
U16
147
0x18
35
0x19
35
Содержание PowerXL DX-NET-ETHERNET2-2
Страница 2: ......