Instruction Leaflet IL040029EN
Effective December 2017
PowerXL DH1 Series VFD
EATON
www.eaton.com
15
International cable and fuse sizes—208 Vac to 240 Vac Ratings
Notes
���
Line and motor cable size is selected according to IEC 60364-5-52:2009 Table B.52.4 for copper conductor with PVC insulation with a wiring condition of ambient temperature 30 °C in air and an installation
method of “B2” (cables in conduit and cable trunking systems). For other wiring conditions, please refer to the standard of IEC 60364-5-52:2009 for suitable cable sizes.
���
Earthing conductor size is determined by the cross-sectional area of phase conductors according to IEC/EN 61800-5-1:2007 Table 5. So if phase conductor size is changed, earthing conductor size should also be
changed accordingly.
���
If power cubes or bypass are used, a Class gG/gL fuse is recommended.
���
FR0 is not available till June 2018.
Frame size
Amp
suffix
208 V input
current
(VT/I
L
)
Current
(VT/I
L
)
at 40 °C
Fuse
rating
(gG/gL)
Mains and
motor cable
Cu (mm
2
)
Terminal cable size
Main terminal
Cu (mm
2
)
Earth terminal
Cu (mm
2
)
FR0
���
4D8
5.6
4.8
10
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
6D6
7.6
6.6
10
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
7D8
9
7.8
16
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
FR1
4D8
4.4
4.8
6
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
6D6
6.1
6.6
10
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
7D8
7.2
7.8
16
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
011
10.2
11
16
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
012
11.6
12.5
16
3*1.5+1.5
0.2–6 solid or
0.2–4 stranded
0.75–6
FR2
017
16.3 17.5
20
3*4+4
0.5–16
4–16
025
23.2
25
32
3*4+4
0.5–16
4–16
031
29
31
32
3*6+6
0.5–16
4–16
FR3
048
44.2
48
50
3*16+16
16–35
2.5–25
061
56
61
63
3*16+16
16–35
2.5–25
FR4
075
64.6 75
80
3*25+16
16–50
6–50
088
78
88
100
3*35+16
16–50
6–50
114
94.3
114
125
3*50+25
16–50
6–50
FR5
143
129
143
160
3*70+35
50–185
10–120
170
157
170
200
3*95+50
50–185
10–120
211
189
211
250
3*150+95
50–185
10–120
FR6
261
242.8
261
400
2*(3*70+35)
2*(50–150)
35–150
312
290.3
312
400
2*(3*95+50)
2*(50–150)
35–150