6 Parameters
102
DC1 Frequency Inverter
10/12 MN04020003Z-EN
www.eaton.com
P-47
175
✓
rw
Analog input 2 signal format
t 4-20
V0-10
0 - 10 V signal
A0-20
0 - 20 mA
t4-20
4 - 20 mA (
≦
3 mA
→
error message: 4-20F)
r4-20
4 - 20 mA (
≦
3 mA
→
delay time 1)
t20-4
20 - 4 mA (
≦
3 mA
→
error message: 4-20F)
r20-4
20 - 4 mA (
≦
3 mA
→
delay time 1)
P-48
176
✓
rw
0.0 - 25.0 s
Standby time
0 = Deactivated
The drive will switch to standby mode (i.e., output deactivated) if the
minimum speed (P-02) remains constant during the length of time spec-
ified here.
20
P-49
177
✓
rw
0.0 - 100.0 %
PI feedback wake up level
Error value (difference between PI setpoint and process value) for the
PI controller. If the value measured by the PI controller is higher than
this value, the drive will leave the stand-by mode.
0
P-50
178
✓
rw
CANopen baud rate for CANopen communications
2
0
125 kbit/s
1
250 kBit/s
2
500 kBit/s
3
1000 kBit/s
P00-…-Display values
P00-01
20
ro
%
Analog input 1
100 % = Maximum input voltage
P00-02
21
ro
%
Analog input 2
100 % = Maximum input voltage
P00-03
23
ro
Hz/rpm
Frequency reference value / Motor shaft speed
Shown in Hz if P-10 = 0; otherwise shown in rpm
P00-04
11
ro
DI1 - DI4 status
Digital inputs 1 - 4
State of the frequency inverter‘s digital input
P00-05
ro
0
reserved
P00-06
ro
0
reserved
P00-07
ro
V
Motor voltage: the value of the rms voltage being applied at the motor
P00-08
23
ro
V
Internal DC bus voltage
P00-09
24
ro
°C
Unit Temperature
Heatsink temperature in °C
P00-10
ro
HH:MM:SS
The frequency inverter’s operating time
Not affected when the parameters are reset to their default settings.
PNU
ID
Access rights
Value
Description
DS
RUN
ro/rw
Содержание PowerXL DC1
Страница 1: ...Manual PowerXL DC1 Frequency Inverter 10 12 MN04020003Z EN...
Страница 4: ...II...
Страница 12: ...0 About this manual 0 5 Units 8 DC1 Frequency Inverter 10 12 MN04020003Z EN www eaton com...
Страница 32: ...1 DC1 device series 1 12 Service and warranty 28 DC1 frequency inverter 10 12 MN04020003Z EN www eaton com...
Страница 52: ...2 Engineering 2 5 Motor and Application 48 DC1 Frequency Inverter 10 12 MN04020003Z EN www eaton com...
Страница 190: ...9 Appendix 9 9 Sinusoidal filter 186 DC1 Frequency Inverter 10 12 MN04020003Z EN www eaton com...