Eaton Power Xpert 9395P Скачать руководство пользователя страница 9

INTRODUCTION

Power Xpert 

9395P Field Installed UPM Mechanical Installation Manual  

S

  P-164000503 Rev 1

 

1-3

1.3

Symbols, Controls, and Indicators

The following are examples of symbols used on the UPS or accessories to alert you
to important information:

RISK OF ELECTRIC SHOCK - 

Observe the warning associated with the risk of electric

shock symbol.

CAUTION:  REFER TO OPERATOR'S MANUAL - 

Refer to your operator's manual for

additional information, such as important operating and maintenance instructions.

This symbol indicates that you should not discard the UPS or the UPS batteries in the
trash. This product contains sealed, lead‐acid batteries and must be disposed of
properly. For more information, contact your local recycling/reuse or hazardous waste
center.

This symbol indicates that you should not discard waste electrical or electronic
equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse
or hazardous waste center.

1.4

For More Information

Refer to the following manuals for additional information:

S

Eaton Power Xpert 9395P UPS (650 900 kVA) Installation and Operation Manual

S

Eaton Power Xpert 9395P UPS (1000-1200 kVA) Installation and Operation Manual

These manuals describe:

S

UPS cabinet, optional components, and accessory installation instructions,
including site preparation, planning for installation, and wiring and safety
information. Detailed illustrations of cabinets and optional accessories with
dimensional and connection point drawings are provided.

S

UPS operation, including UPS cabinet controls, functions of the UPS, standard
features and optional accessories, procedures for starting and stopping the UPS,
and information about maintenance and responding to system events.

S

Communication capabilities of the UPS system.

Visit www.eaton.com/powerquality or contact Eaton service representative for
information on how to obtain copies of these manuals.

Содержание Power Xpert 9395P

Страница 1: ...Eaton Power Xpert 9395 High Performance Field Installed UPM Mechanical Installation Manual Referenced throughout as 9395P...

Страница 2: ......

Страница 3: ...Eaton Power Xpert 9395 High Performance Field Installed UPM Mechanical Installation Manual Referenced throughout as 9395P...

Страница 4: ...et conserver ce manuel afin de pouvoir vous y reporter ult rieurement WARNING This is a product for restricted sales distribution to informed partners EN IEC 62040 2 Installation restrictions or addit...

Страница 5: ...2 Safety Warnings 2 1 3 Field Installed UPM Installation Plan and Unpacking 3 1 3 1 Creating an Installation Plan 3 1 3 2 Preparing the Site 3 1 3 3 Inspecting and Unpacking the FI UPM Cabinet 3 6 4...

Страница 6: ...ew 3 4 Figure 3 3 FI UPM Cabinet Dimensions Top View 3 4 Figure 3 4 FI UPM Cabinet Dimensions Bottom View 3 5 Figure 3 5 FI UPM Cabinet Dimensions Bottom View with Mounting Brackets 3 5 Figure 3 6 FI...

Страница 7: ...1 become void This service is offered as part of the sales contract for the FI UPM Contact an Eaton service representative in advance usually a two week notice is required to request service 1 1 Usin...

Страница 8: ...INTRODUCTION Power Xpert 9395P Field Installed UPM Mechanical Installation Manual S P 164000503 Rev 1 1 2 Figure 1 1 Power Xpert 9395P Field Installed UPM...

Страница 9: ...WEEE in the trash For proper disposal contact your local recycling reuse or hazardous waste center 1 4 For More Information Refer to the following manuals for additional information S Eaton Power Xpe...

Страница 10: ...he following S Scheduling initial startup S Regional locations and telephone numbers S A question about any of the information in this manual S A question this manual does not answer Please call the E...

Страница 11: ...ontaminants Ambient temperature must not exceed 40 C 104 F Do not operate near water or excessive humidity 95 maximum The system is not intended for outdoor use S Ensure all power is disconnected befo...

Страница 12: ...er les portes de l onduleur ferm es et les panneaux avant en place pour garantir une circulation ad quate de l air de refroidissement et pour prot ger le personnel des tensions dangereuses dans l unit...

Страница 13: ...procedures and illustrations in paragraph 3 2 and Chapter 4 to create a logical plan for installing the system 3 2 Preparing the Site For the FI UPM to operate at peak efficiency the installation sit...

Страница 14: ...net Clearances From Top of Cabinet 457 2 mm 18 minimum clearance for ventilation From Front of Cabinet 914 4 mm 36 working space From Back of Cabinet None Required From Right Side of Cabinet None Requ...

Страница 15: ...LLATION PLAN AND UNPACKING Power Xpert 9395P Field Installed UPM Mechanical Installation Manual S P 164000503 Rev 1 3 3 Dimensions are in millimeters inches 1880 74 0 735 9 29 0 Figure 3 1 FI UPM Cabi...

Страница 16: ...al Installation Manual S P 164000503 Rev 1 3 4 871 34 3 831 5 32 7 39 5 1 6 192 4 7 6 149 2 5 9 Dimensions are in millimeters inches Figure 3 2 FI UPM Cabinet Dimensions Right Side View Front Dimensio...

Страница 17: ...3 5 Front 602 8 23 7 213 8 4 Dimensions are in millimeters inches Figure 3 4 FI UPM Cabinet Dimensions Bottom View Front 12 7 0 5 X 15 8 0 62 Slot 6X 830 32 7 346 13 6 346 13 6 69 2 7 39 2 1 54 59 2...

Страница 18: ...et is heavy see Table 3 1 on page 3 2 If unpacking and unloading instructions are not closely followed the cabinet may tip and cause serious injury AVERTISSEMENT Les sections de l onduleur sont lourde...

Страница 19: ...ncliner les armoires FI UPM plus de 10 degr s de la verticale puisqu elles pourraient se renverser 3 Set the pallet on a firm level surface allowing a minimum clearance of 3m 10 ft on each side for re...

Страница 20: ...INSTALLED UPM INSTALLATION PLAN AND UNPACKING Power Xpert 9395P Field Installed UPM Mechanical Installation Manual S P 164000503 Rev 1 3 8 Figure 3 7 Power Xpert 9395P FI UPM Cabinet as Shipped on Pa...

Страница 21: ...r remove the shield before operating the UPS system Once the debris shield is removed do not place objects on the ventilation grill S A FI UPM is always designated as UPM 4 4 2 Unloading the FI UPM Ca...

Страница 22: ...3 6 for the FI UPM cabinet center of gravity measurements 2 Remove the three bolts securing the left side shipping bracket to the cabinet and three bolts securing the bracket to the pallet see Figure...

Страница 23: ...UPM 1 Remove the wire entry plate located on the bottom left side of the UPS cabinet see Figure 4 3 2 If not already removed remove the wire entry knockout located on the top left side of the UPS cab...

Страница 24: ...the bracket with the screws from the hardware kit 8 Reinstall the FI UPM front panel removed in Step 6 and secure with the retained hardware 9 If permanently mounting the system proceed to Step 10 oth...

Страница 25: ...ntract for the FI UPM Contact an Eaton service representative in advance usually a two week notice is required to reserve a preferred startup date 4 6 Completing the Installation Checklist The final s...

Страница 26: ...the FI UPM to the UPS Air conditioning equipment is installed and operating correctly The area around the installed UPS system is clean and dust free It is recommended that the UPS be installed on a...

Страница 27: ..._________________ _________________________________________________________________________ _________________________________________________________________________ __________________________________...

Страница 28: ...FIELD INSTALLED UPM INSTALLATION Power Xpert 9395P Field Installed UPM Mechanical Installation Manual S P 164000503 Rev 1 4 8 This page intentionally left blank...

Страница 29: ...new location by someone other than an authorized Eaton Customer Service Engineer in USA or Agent outside of USA or c if the Product s serial numbers have been removed or are illegible Any Warranted It...

Страница 30: ...WARRANTY Power Xpert 9395P Field Installed UPM Mechanical Installation Manual S P 164000503 Rev 1 W 2 This page intentionally left blank...

Страница 31: ......

Страница 32: ...P 1640005031 P 164000503 1...

Отзывы: