MaGnuM PRoDuct GuiDe
CA013002EN—April 2017 www.eaton.com
35
Magnum IEC - Product specific information
Magnum IEC breaker product family continued (15 through 25)
Undervoltage Release (UVR)
or 2nd Shunt Trip (ST)
N
A
R
C
H
D
E
F
G
X
J
K
1
2
3
4
6
B
O
I
Q
9
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
None
UVR (110–127 Vac)
UVR (208–240 Vac)
UVR (24 Vdc)
UVR (48 Vdc)
UVR (60 Vdc)
UVR (110–125 Vdc)
UVR (220–250 Vdc)
UVR (32 Vdc)
UVR (380–415 Vac)
UVR (480 Vac)
UVR (600 Vac)
2
nd
ST (110–127 Vac Vdc)
2
nd
ST (208–250 Vac Vdc)
2
nd
ST (24 Vdc)
2
nd
ST (48 Vdc)
2
nd
ST (60 Vdc)
2
nd
ST (110–127 Vac/
Vdc 100% duty)
2
nd
ST (220–250 Vac/
Vdc 100% duty)
2
nd
ST (24 Vdc 100% duty)
2
nd
ST (48 Vdc 100% duty)
2
nd
ST (60 Vdc 100% duty)
Motor operator
M
N
W
T
P
L
K
S
1
2
4
8
5
9
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Manual operated
110–125 Vac (5-sec)
110–125 Vdc (5-sec)
220–250 Vdc (5-sec)
208–277 Vac (5-sec)
24 Vdc (5-sec)
48 Vdc (5-sec)
60 Vdc (5-sec)
110–125 Vac (3-sec)
220–250 Vac (3-sec)
24 Vdc (3-sec)
48 Vdc (3-sec)
110–125 Vdc (3-sec)
220–250 Vdc (3-sec)
Spring Release Device
(SRD)
N
A
R
C
H
S
=
=
=
=
=
=
None
110–127 Vac/Vdc
208–240 Vac/Vdc
24 Vdc
48 Vdc
60 Vdc
Auxiliary switch
N
2
4
6
=
=
=
=
None
2A/2B
4A/4B
6A/6B
Shunt Trip
Attachment (STA)
N
A
R
C
H
B
S
D
K
J
6
=
=
=
=
=
=
=
=
=
=
=
None
110–127 Vac/Vdc
208–240 Vac/Vdc
24 Vdc
48 Vdc
110–127 Vac/Vdc
(100% duty)
220–250 Vac/Vdc
(100% duty)
24 Vdc (100% duty)
48 Vdc (100% duty)
60 Vdc (100% duty)
60 Vdc
Bell Alarms Switch (OTS) with
2a/2b contacts and/or mechanical
trip indicator
Mech.
trip
indicator
Mech.
inter-
lock for
manual
reset
OTS
switch
with two
form C
contacts
E
N
Y
M
L
F
G
H
I
J
K
=
=
=
=
=
=
=
=
=
=
=
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
Yes
No
Yes
Yes with
24V reset
Yes with
120V
reset
Yes with
240V
reset
Yes with
24V reset
Yes with
120V
reset
Yes with
240V
reset
Future use
X
= All ACBs
MW N 5 12 4 V E A 03 MT 6 M C J 2 Y C N M W X
ACB shipping instructions
A
B
F
A
C
P
S
W
=
=
=
=
=
=
=
=
Fixed breaker alone with
door kit
Fixed breaker alone with door
kit and pre-wired
Fixed breaker alone without
door kit
D/O ACB only without door kit
D/O ACB in cassette
(un-wired)
D/O ACB in cassette
(pre-wired)
D/O ACB in cassette (shutters)
D/O ACB in cassette
(pre-wired and shutters)
Double frame D/O ACBs ship
without cassette.
Padlock provisions for blocking
close and/or open ACB manual
pushbuttons
N
M
P
C
H
=
=
=
=
=
None
Metal (block close and open)
Plastic (block close and open)
Metal (block close only)
Plastic (block close only)
Operations counter and/
or keylock provisions
Counter
Keylock
provisions
N
K
C
R
S
A
Y
L
H
E
=
=
=
=
=
=
=
=
=
=
No counter
No counter
No counter
No counter
No counter
Counter
Counter
Counter
Counter
Counter
No locks
Kirk lock
Castell lock
Ronis lock
CES lock
No lock
Kirk lock
Castell lock
Ronis lock
indicator
CES lock
Latch check switch/trip unit
metering voltage connection for
digitrip 1150 trip unit
Latch
check
switch
1150 voltage
connection
N
=
M
=
L
=
Y
=
C
=
D
=
None
None
LCS wired
to SRD
LCS Wired
to SRD
LCS Wired
External
LCS Wired
External
Upper terminals
Lower terminals
Upper terminals
Lower terminals
Upper terminals
Lower terminals
Exclusionary rules apply . Refer to price list . Confirm all final part
numbers with Eaton . Format structures subject to modifications
and additions without notice .