background image

Dimn ‘a’

Dimn ‘a’

Instruction Leaflet

K1121V11

Leat

February 2020

 Product luminaires comply with EN60598 and are suitable for use in normal interior conditions.

o

o

 This luminaire has an ambient temperature range of -10 C to 25 C for the non-emergency version

o

o

 For Emergency variants - This luminaire has an ambient temperature range of 5 C to 25 C, to ensure the batteries work correctly

Recessed - Bracket Installation

Fixing Centres (per fitting)

1.0m
1.5m
2.0m

700mm

centre fixing

3.0m

1200mm
1700mm

IMPORTANT: 

Once brackets

are fully installed. Plaster surface
before installing the Leat.

a)

Cut aperture to required size.

Using the flat bracket (sold separately) as a drilling template, drill 4 x holes 

5mm dia, through pilot holes. See ‘Bracket Orientation’.

Counter sink the drilled holes so c/sk screws (supplied) sit flush with 

the plasterboard.

Dimn ‘a’

Drilling Direction

240mm MAX

Plasterboard

160mm MIN

44x44mm

Wooden

Battens

Recommended Wooden Batten Spacing

For Plasterboard Support

Drilling Direction

b)

Secure each slider to 

plasterboard using M5 

c/sk screws supplied

Dim ‘a’

Trimmed

Trimless

79.0mm

76.0mm

Bracket Orientation

When using the flat bracket for the drill hole locations make sure the metalwork is 

in the correct orientation.

The image on the left shows the orientation for the trimless variant and the image on 

the right shows the orientation for the trimmed version.

c)

Fold flat bracket over and fix spring clip.

Fit main bracket into slider brackets. Ensure that

dimension ‘a’ from bottom of plasterboard to the inside 

face of main face is adhered to. Tighten slider 

bracket screws to hold main bracket in place.

D

im ‘a’

Aperture

Trim - 65.5mm wide

Trimless - 57.0mm wide

Fixing crs

Aperture

Trim - Run 8.0mm

Trimless - Run 10.5mm

Отзывы: