User Menu Options
Page 48
The keypad gives a double-beep confirmation tone and you will see
the results of the test:
The bottom line shows the name of the user the proximity tag is
allocated to (or "Unknown" if the proximity tag is not recognised).
3.
Repeat step 2 for the other proximity tags.
4.
Press
to end the test.
Testing ARC reporting
Master and admin users can use
Test
– ARC Reporting
to test the
connection to Alarms Receiving Centres (ARCs).
To carry out the test:
1.
Select
Test
– ARC Reporting
.
The following is displayed:
2.
Use
or
to choose the communication method you want to test,
then press
. The ARC may use Ethernet (
Panel Ethernet
), GSM or
PSTN (the latter two require the control unit to have an appropriate
plug-on module fitted).
Note:
The installer may have configured more than one
communication method to the ARC: Ethernet and GSM, or Ethernet
and PSTN. The installer specifies which of the two methods has the
highest priority. During normal operation, the control unit uses the
method that has the highest priority, and uses the second method only
if the first fails.
The following is displayed:
3.
Use
or
to choose one of the two recipients selected by the
installer. Each recipient is a separate telephone number or IP address
to the ARC. Depending on how the installer has configured