background image

User Menu Options 

Page 39 

 

Note:

 If you have a proximity tag that is already allocated, you can 

find out who it belongs to by using 

Test 

– Prox Tag

 (page 42). 

7. 

For user types that can set the system, you can assign a remote 
control that is not already assigned to another user: 




 

To assign a remote control, press any button on the remote control, 
then (if you are using a partitioned system), choose one partition to 
assign to the remote control.  

 

If you do not want to assign a remote control, press 

 at the above 

prompt. 

 

Note:

 If you have a remote control that is already allocated, you can 

find out who it belongs to by using 

Test 

– Remotes

 (page 42). 

8. 

For user types that can set the system, you can assign a radio HUA 
(Hold-Up Alarm) device: 




 

Press a button on an unallocated HUA transmitter until you see "HUA 
added", or 

 if you do not want to assign one. 

 

Note:

 If you have an HUA transmitter that is already allocated, you 

can find out who it belongs to by using 

Test 

– Hold Up Alarms

 (page 

42). 

 

Note:

 While you are registering a new HUA transmitter, the control 

unit will not respond to an alarm signal from any radio HUA it has 
already learnt. 

9. 

If you are adding a Shunt Code user, press 

 or 

 followed by 

 to 

select the shunt group to assign to the user: 




 

The * indicates the currently-selected shunt group. 

10.  The control unit confirms that the user has been added: 



Содержание i-on30R

Страница 1: ...i on30R 40H Next Generation Security System Administration and User Guide Issue 2 Control unit software version 5 01...

Страница 2: ...ot limited to damage or loss of use of equipment plant or power system cost of capital loss of power additional expenses in the use of existing power facilities or claims against the purchaser or user...

Страница 3: ...setting the system using a keypad 17 Unsetting the system using a keypad 18 Using a two way keyfob style remote control 19 Setting the system 20 Unsetting the system 20 Querying the set unset status...

Страница 4: ...g the system 42 Testing sirens and sounders 42 Testing a wired keypad 43 Performing a walk test 44 Testing outputs 45 Testing remote controls 46 Testing user HUAs 47 Testing proximity tags 47 Testing...

Страница 5: ...your system may have been configured by the installer as a part setting system or a partitioned system These two modes are explained below Part setting mode In part setting mode the control unit can s...

Страница 6: ...it into separate alarm systems A zone is armed only when ALL of the partitions that it belongs to are set If you unset any of the partitions that a zone belongs to the control unit will unset that zon...

Страница 7: ...Two button Hold Up Alarm 3 One way remote control 4 Two way remote control 5 Keypad i kp01 6 Keypad KEY K01 KEY KP01 KEY KPZ01 or KEY RKPZ 7 Keypad i RK01 one way radio arming keypad 8 Keypad KEY FKP...

Страница 8: ...message SMS command message control If the control unit has appropriate hardware fitted you can change or query the status of the alarm system using commands contained within SMS text messages sent fr...

Страница 9: ...er menu options Each alarm system can have one or more keypads up to a limit depending on the control unit used The i on Next Generation range of alarm systems supports several different types and sty...

Страница 10: ...lay shows messages and prompts to guide you through actions such as setting unsetting acknowledging alarms and using the user options When the system is idle either while set or unset the display show...

Страница 11: ...tention to special events Setting and unsetting keys 4 on Figure 2 An installer can use the Installer menu to edit the details of the keypad and specify the action of the A B C and D keys In a part se...

Страница 12: ...taller Alpha numeric keys 6 on Figure 2 These are used for entry of text or access codes Set Unset status LEDs 7 on Figure 2 These LEDs i kp01 only can show the set status of the system In a part sett...

Страница 13: ...r unsetting the system or operating output devices from a distance There are two types of remote control The i FB01 This is a one way remote control that has four buttons and a small LED that glows wh...

Страница 14: ...Master user This user is able to carry out all user actions A master user can for example set or unset the system and access all options in the user menus including the ability to add or delete other...

Страница 15: ...nd the ARC what action the ARC should take on receiving a duress message Guard A guard user can only unset the system when it is in alarm and set it again A guard user has no access to the user menu I...

Страница 16: ...alid access code at the keypad or by presenting a proximity tag Access codes and proximity tags are unique to each user and can be used interchangeably at any time Users can also use a remote control...

Страница 17: ...n how your installer has programmed the system you may receive a phone call from the installer to request access Eaton SecureConnect Eaton SecureConnect allows you to monitor and control your alarm sy...

Страница 18: ...ether the system is set or unset For example Fire and smoke detectors flood sensors Hold Up Alarm buttons or emergency exits Monitors for machinery for example freezers or other type of technical alar...

Страница 19: ...set all partitions This is available only if there are zones that the installer has given the Part Set attribute Partitions partitioned system only To choose the partition s to set and whether to ful...

Страница 20: ...on your entry exit route the keypad gives an interrupted setting tone this is normal The system sets when one of the following occurs depending on how the system is configured Immediately instant set...

Страница 21: ...ntry exit route are inactive If there is more than one zone active the display changes every three seconds to show each zone in turn Quick setting the system using a keypad Your installer may have ena...

Страница 22: ...the tone go directly to the keypad since you will have limited time to unset the system before it generates an alarm 3 Enter your access code or present your proximity tag to the keypad If you enter...

Страница 23: ...installer When you operate the buttons the control unit sends back signals that light up one or more LEDs on the fob These show whether your system has set or if there has been an alarm while you hav...

Страница 24: ...r three seconds This is your confirmation that the control unit has set the system Unsetting the system Note An administrator can disable the ability for remote controls to unset the system see page 6...

Страница 25: ...l four LEDs glow green for three seconds This is your confirmation that the control unit has generated the alarm Using a one way remote control The one way remote control has four buttons and a small...

Страница 26: ...o set the system you will not hear the exit warning tone Instead you will hear a single beep Try pressing A again on your remote control If set up by the installer the system will omit the active dete...

Страница 27: ...e sure the system is in standby 2 Enter a valid access code or present your proximity tag to the keypad 3 Press A To set the system fully part setting system or to set partition 1 B To set part set B...

Страница 28: ...imited time to unset the system before it generates an alarm 3 Enter your access code or present your proximity tag to the keypad 4 Press Using SMS command messaging Using a mobile phone or other mess...

Страница 29: ...is a failure of a communications link from the control unit When an alarm occurs the control unit normally activates internal sounders and depending on severity external siren strobe units Table 1 sho...

Страница 30: ...Quiet beeping once per second from wired keypads A system fault detected by the control unit such as a mains failure or communications line fault See page 29 Other alarm actions In addition to soundin...

Страница 31: ...ch message acknowledgement Function Key End this call and let the control unit contact the other nominated persons for this alarm 5 Play message again 3 Clear down and do not call any of the other nom...

Страница 32: ...e or device that generated the alarm For example 4 Press to indicate that you have acknowledged the alarm message The system returns to standby and is ready to set again 5 If the alarm message include...

Страница 33: ...the ARC and quote the 4 digit number 4 If satisfied with your identity the ARC provides a reset code 5 Enter the reset code at the keypad to reset the alarm Accidental alarms Your installer may have c...

Страница 34: ...xample The bottom line may alternate between displaying the zone number and name if applicable 4 Press to acknowledge that you have read the alert Repeat this step for any other alerts that may be act...

Страница 35: ...r menu and the availability depending on the user type Some options may not be visible depending on the hardware fitted MENU Option Master Users Admin Users Normal Users Partition Users Level 4 Users...

Страница 36: ...System Config Facilities On Off Chime Remote Access Level 4 Updates Set Date Time Calendar Set Add Event Edit Event Event name Event time Event day Ward Partitions Warning time Warning tone Delete ev...

Страница 37: ...s followed by to select the option you require Refer to the following sections for information about each option 5 To leave the menu and return to the standby screen press if necessary several times E...

Страница 38: ...he zone is triggered while the system is set For example if a zone protects a garage door you may want to omit the zone to enable the delivery of a parcel while the system is set Note The control unit...

Страница 39: ...of one or more zones You should agree with the installer what zones need to go into each shunt group and record that information A zone can be in more than one shunt group Once the shunt groups are d...

Страница 40: ...a If you are a normal or partition user you can use the Users option to Change your access code Add or delete your own proximity tag remote control or radio Hold Up Alarm HUA transmitter In a partiti...

Страница 41: ...tition option to specify the partition that the remote control can set unset etc Use or to scroll through the partitions and to choose Yes or No Press on completion You should delete your remote contr...

Страница 42: ...a partitioned system and are adding a user other than a master user or Shunt Code user you are prompted to specify the user s partitions By default a new user belongs to all partitions Press or to sc...

Страница 43: ...ed you can find out who it belongs to by using Test Remotes page 42 8 For user types that can set the system you can assign a radio HUA Hold Up Alarm device Press a button on an unallocated HUA transm...

Страница 44: ...w user with a new code To edit a user 1 Select Users Edit User 2 Press or followed by to select the user you wish to edit Alternatively enter the user number e g 004 and press 3 Press or followed by t...

Страница 45: ...Press or followed by to select the user you wish to delete Alternatively enter the user number e g 004 and press You will see for example 3 Press to delete the user or if you have changed your mind Vi...

Страница 46: ...eyswitch zone used to set unset 034 054 Remote reset carried out by ARC 035 055 Action through Downloader software 036 056 Action through virtual keypad 037 057 Action through SMS command 040 060 Acti...

Страница 47: ...st Testing a wired keypad Note You can test only the keypad you are currently using you cannot test a keypad remotely To carry out the test 1 Select Test Wired Keypad The bottom line of the display sh...

Страница 48: ...2 Press or to select one of the following Once Causes keypads and loudspeakers to chime only once for each zone that is triggered during the walk test On Generates a chime every time a zone is trigge...

Страница 49: ...you can press and scroll through the untested zones press again to continue with the test 6 If you wish you can press to finish the test early 7 Once all zones are tested you will see for example Tes...

Страница 50: ...ry out the test 1 Select Test Remotes The following is displayed 2 Press and hold a button on the device you wish to test until the transmit LED on the device flashes The keypad gives a double beep co...

Страница 51: ...before the test The keypad gives a double beep confirmation tone and you will see the results of the test The top line shows the name of the user the device is allocated to The bottom line shows the s...

Страница 52: ...e communication method you want to test then press The ARC may use Ethernet Panel Ethernet GSM or PSTN the latter two require the control unit to have an appropriate plug on module fitted Note The ins...

Страница 53: ...this option to enable or disable the chimes that occur when a zone is triggered that has a Chime attribute as set up by the installer For most zone types a chime occurs only when the system is unset...

Страница 54: ...obtain its time automatically from an SNTP server The internal clock adjusts itself for daylight saving in Spring and Autumn Configuring calendar sets Master and admin users can use System Config Cal...

Страница 55: ...is 01 00 to 02 00 For EU control units this time is 02 00 to 03 00 If the control unit unsets any part of the system at these times it will NOT set the system again when the clock changes back to Wint...

Страница 56: ...Warning Time Specify the period in minutes you want the control unit to sound the warning tone before the start of a setting event Enter between 1 and 30 minutes The default is 10 There is no specifi...

Страница 57: ...on to start then to display the next prompt The time 00 00 is midnight at the beginning of a new day Exception Start Date Specify the date you want the exception to start for example 31 12 for 31 st D...

Страница 58: ...ing a calendar set event will also fail Before the time of a setting event the control unit starts the calendar set warning tone as usual but at the setting time the control unit will not set the syst...

Страница 59: ...P Address The recipient s IP address Press when you have finished editing the setting and if required select another setting to edit 4 Press several times to exit Editing outputs Master and admin user...

Страница 60: ...seconds you want the output to remain active If you specify zero seconds the output will not operate You can use On Time Off Time and Days to specify a schedule for the output to activate and deactiva...

Страница 61: ...amming of the buttons You can use System Config Remotes Edit to re program buttons on a one way remote control or the button on a two way remote control after the devices have been assigned to a user...

Страница 62: ...ol d Use or followed by to select the button you wish to re program The top line of the display shows the identity of the remote control the button you pressed or selected and the name of the owner Fo...

Страница 63: ...rt Set All partitioned system Part sets all partitions that the user belongs to Partitions partitioned system Full sets or part sets selected partitions that the user belongs to After selecting this o...

Страница 64: ...specific remote control 1 Select System Config Remotes Delete The following is displayed 2 Press the button on the remote control you want to delete Alternatively if you do not have the remote contro...

Страница 65: ...ownloader software via a telephone connection or across an Ethernet network The installer can use Downloader to configure your alarm system Depending on how the installer has configured your system yo...

Страница 66: ...and the type is W wired The bottom line shows the name of the output which may be the same as the address and whether the output is currently on or off 2 Press or to select the output 3 Press or to sw...

Страница 67: ...About The following is displayed 2 Press or followed by to select the option you require 3 If applicable press or followed by to select the sub option 4 If applicable press or to display further infor...

Страница 68: ...ct is a trademark of Eaton www touchpoint online com Product Support UK Tel 44 0 1594 541978 Available between 08 30 to 17 00 Monday to Friday email securitytechsupport eaton com Part Number 12838021...

Отзывы: