3
GFX Manual
EATON
GFX Installation and Operation Manual April 2020 www.eaton.com
Electrical specifications
Short circuit protection
Yes
Short condition: output to battery &
input to GND
CANH & CANL pins: Up to 36V
TX & RX pins: Up to 32V
Reverse polarity
Yes
Up to -36V
Hot plug
Yes
Live connection and disconnection to
power supply
Connector
Supply and I/O connector Deutsch DTM04-08PA
Male type (8 pin)
Mating connector
Deutsch DTM06-08SA
Female type (8 pin)
GPS antenna connector
SMA Female Board/
bulkhead mount connector
Female type
Environmental specifications
Operating temperature
-40°C to +85°C
Storage temperature
-40°C to +85°C
Humidity
90% RH
Altitude
40000 ft
Air shipment , Device off state
Mechanical shock
50Grms, 11mSec
30Grms, 18mSec
6 pulses at each axis,
Total: 36 pulses
10 pulses at each axis,
Total: 60 pulses
Ingress protection
IP67
ISO 20653 (Road vehicles - Degrees
of protection (IP code)
Protection of electrical equipment
against foreign objects,
water and access
Salt spray
96 hrs. in salt
fog atmosphere
Chemical resistance
Cab mounting
Alcohol, Detergents, Diesel fuel,
Waxes, Spray paint,
Hydraulic fluid etc.
Free fall
<1m
Vibration
Sine sweep
Random vibration
10Hz to 2000Hz, 3.5Grms
10Hz to 2000Hz, 2.18Grms
Communication protocols
CAN
SAE J1939
Baud rate 250Kbps
Serial
RS232
Default : 115200 bps
Configurable baud rate
9600/19200/38400/57600/115200 bps
LED indication
Power ON / OFF
Green
Continuous ON when powered up
Diagnostic / health
monitoring
Red
Continuous ON when faults persist
•
Overvoltage (>36V) & under voltage (<5V)
•
GPS antenna open & short
•
Over temperature fault (95°C)
•
GPS and IMU fault
European Commission Directives
Electromagnetic Compatibility (EMC) Directive 2014/30/EU
EN ISO 14982:2009
Agriculture and Forestry machinery
Conducted Electrical
Transient Pulses
ISO7637:2004
Level: IV for 12V & 24V
(all pulses)
Radiated Emission
CISPR 25:2016
30MHz to 1000MHz
Bulk Current Injection ISO11452-
4:2011
Functional Class A
20MHZ-200MHZ, 60mA
Radiated Immunity
ISO11452-
2:2004
Functional Class A
200MHZ to 1GHZ, 30V/m
ESD
ISO 10605:2008 Functional Class A - Contact
& Air discharge (Powered and
Unpowered)
Direct discharge (3 pulses
with > 1s interval)
Contact: ±4kV
Air: ±4kV
Indirect Discharge: (50 pulses
with > 50ms interval)
±4kV
Radio Equipment Directive (RED) 2014/53/EU
ETSI EN 301 489-19 V2.1.0:2017
EMC for Radio Equipment and Services
Conducted Electrical
Transient Pulses
ISO7637:2004
Level: IV for 12V & 24V (all
pulses)
Conducted Immunity
IEC 61000
4-6:2013
Functional Class A 150KHZ-
80MHZ, 3Vrms
Conducted Emission Reference
Clause 8.3
CISPR 32:2015 /
EN 55032:2015
Quasi-peak: Product Class A
0.15-0.5MHZ: 79dB(uV)
0.5-30MHZ: 73dB(uV)
Average: Product Class A
0.15-0.5MHZ: 66dB(uV)
0.5-30MHZ: 60dB(uV)
Radiated Immunity
IEC 61000
4-3:2006
80MHZ to 6GHZ, 3V/m,
Class A
Radiated Emission
EN 55032
30MHz to 6GHz
ETSI EN 303 413 V1.1.1 (2017-06)
Harmonised EU standard for GNSS essential requirement
Spurious Emission
Reference:
Clause No 4.2.2
30MHz-8.3GHz (Radiated &
Conducted Method)
Adjacent
Frequency band
Reference:
Clause No 4.2.1
Δ C/N0 ≤ 1 dB
Conducted Method
Low Voltage (LVD) Directive 2014/35/EU2014/53/EU
IEC 62368-1:2014 Safety: Audio/video, information and communication technology
equipment - Part 1: Safety requirements (Hazard Based Safety Standard)
EN 62479:2010
Health: Assessment of the compliance of low-power electronic and
electrical equipment with the basic restrictions related to human
exposure to electromagnetic fields (10 MHz to 300 GHz)
RoHS 2 Directive 2011/65/EU
Restriction of the Use of Certain Hazardous Substances
in Electronic and Electrical Equipment
Other directives
FCC SDoC
(Suppliers
Declaration of
Conformity)
FCC part 15B
Part 15-Low Power Unlicensed Devices
Radiated Emissions Section 15.109
(30MHz to 1GHz)