background image

Instruction Booklet  

IB0162063EN

Effective January 2014

O & M Manual for the EGS Metered, Service

Entrance Automatic Transfer Switch with Relay Control

Eaton 

1000 Eaton Boulevard

Cleveland, Ohio 44122

Canadian Operations

5050 Mainway

Burlington, ON L7L 5Z1

Canada

1-800-268-3578

EatonCanada.ca

© 2014 Eaton Corporation

All Rights Reserved

Printed in Canada

Publication No. IB0162063EN

January 2014

Eaton is a registered trademark

of Eaton Corporation.

All trademarks are property of their

respective owners.

This instruction booklet is published solely for information purposes 

and should not be considered all-inclusive. If further information is 

required, you should consult an authorized Eaton sales representa-

tive.
The sale of the product shown in this literature is subject to the 

terms and conditions outlined in appropriate Eaton selling policies 

or other contractual agreement between the parties. This literature 

is not intended to and does not enlarge or add to any such contract. 

The sole source governing the rights and remedies of any purchaser 

of this equipment is the contract between the purchaser and Eaton.

nO WarranTiES, EXPrESSED Or iMPLiED, inCLUDing WarranTiES 

OF FiTnESS FOr a ParTiCULar PUrPOSE Or MErCHanTaBiLiTY, Or 

WarranTiES ariSing FrOM COUrSE OF DEaLing Or USagE OF TraDE, 

arE MaDE rEgarDing THE inFOrMaTiOn, rECOMMEnDaTiOnS, anD 

DESCriPTiOnS COnTainED HErEin.

 In no event will Eaton be respon-

sible to the purchaser or user in contract, in tort (including negli-

gence), strict liability or otherwise for any special, indirect, incidental 

or consequential damage or loss whatsoever, including but not 

limited to damage or loss of use of equipment, plant or power sys-

tem, cost of capital, loss of power, additional expenses in the use of 

existing power facilities, or claims against the purchaser or user by 

its customers resulting from the use of the information, recommen-

dations and description contained herein.

Содержание EGS Series

Страница 1: ...uipment Description 5 4 Installation and Wiring 8 5 Functional Testing 12 6 Adjustments 13 7 Maintenance and Component Replacement 14 Effective January 2014 Instruction Booklet IB0162063EN O M Manual...

Страница 2: ...e proceeding If fur ther information is required by the purchaser regarding a particular installation application or maintenance activity please contact an authorized Eaton sales representative or the...

Страница 3: ...ear Conversely if connected to the generator power source and the generator power source fails while the utility power source is still unavailable the ATS remains connected to the generator power sour...

Страница 4: ...e when it is within its undervoltage setpoint ranges for the nominal voltage setting Connected Connected is defined as when the input is shorted by an external contact or connection Failed or Fails A...

Страница 5: ...site and ready to be installed the packaging material can be removed Refer to Section 4 of this manual for specific installation instructions 2 3 Storage Although well packaged this equipment is not s...

Страница 6: ...configuration or an under ground one Twin 2 hub openings on the top of the enclosure will accept a standard Myers type hub The assembly ships with removable hub closure plates installed over these ope...

Страница 7: ...e lugs sup plied will accommodate the power cables being used Also verify that the cables comply with all local electrical codes Standard ATS equipment as supplied from the factory will accommodate th...

Страница 8: ...range number of Cables per Phase 100 14 1 0 AWG 1 200 4 AWG 300 MCM 1 CaUTiOn iMPrOPEr POWEr CaBLE COnnECTiOnS Can CaUSE EXCESSiVE HEaT anD SUBSEQUEnT EQUiPMEnT FaiLUrE ote N Tighten the cable lugs to...

Страница 9: ...ector switch to the OFF position to prevent an unwanted generator start Control wiring such as the generator transfer wires and utility sensing must be run in a separate conduit from the power cables...

Страница 10: ...ontactor will automatically switch to the UTILITY position WARNING CONTACT WITH ENERGIZED COMPONENTS WILL CAUSE ELECTRICAL SHOCK CAPABLE OF PRODUCING SEVERE PERSONAL INJURY OR DEATH USE EXTREME CAUTIO...

Страница 11: ...DEVICE FAILURE TO FOLLOW THIS PROCEDURE COULD CAUSE SEVERE PERSONAL INJURY AND OR DEATH ALWAYS TURN THE utility POWER OFF AND TURN THE generator IF A GENERATOR CONTROL SELECTOR SWITCH TO THE oFF POSI...

Страница 12: ...inspection and or maintenance Disconnect the line power from the equipment being serviced by opening next highest disconnect device Make certain that any accessory control power is switched off b Ins...

Страница 13: ...IB0162063EN Effective January 2014 O MManualfortheEGSMetered Service EntranceAutomaticTransferSwitchwithRelayControl Eaton Corporation www eatoncanada ca Figure 15 Wiring Diagram for the EGSC ATS Show...

Страница 14: ...B0162063EN Effective January 2014 O MManualfortheEGSMetered Service EntranceAutomaticTransferSwitchwithRelayControl Eaton Corporation www eatoncanada ca 7 3 Maintenance Log Date Action Example 01 01 1...

Страница 15: ...DEATH ALWAYS TURN THE UTILITY SOURCE 1 POWER OFF AND TURN THE GENERATOR SOURCE 2 CONTROL SELECTOR SWITCH TO THE OFF POSITION BEFORE ATTEMPTING TO REPLACE ANY COMPONENTS NOTICE Apply utility source 1 p...

Страница 16: ...thRelayControl Eaton Corporation www eatoncanada ca Figure 16 Dimensions and Plan View of a Service Entrance EGS in 200A 2 2 Hub Openings 5 90 150mm 5 90 150mm 7 81 198mm 36 19 919mm 29 47 749mm 4 69...

Страница 17: ...17 Instruction Booklet IB0162063EN Effective January 2014 O MManualfortheEGSMetered Service EntranceAutomaticTransferSwitchwithRelayControl Eaton Corporation www eatoncanada ca Notes...

Страница 18: ...ractual agreement between the parties This literature is not intended to and does not enlarge or add to any such contract The sole source governing the rights and remedies of any purchaser of this equ...

Отзывы: