6. Function blocks
6.1 Manufacturer function blocks
Example: Shift register DW mode, backward
Figure 172: Shift register SR..: Backwards operation in DW operating mode
Initial situation
– SR..EN is not activated, the function block is not active.
– SR..D2 contains the value 8, a 0 is contained in the other register fields.
Transfer of value
– SR..EN is activated, the function block is active.
– SR..I2 has the value 10.
– With the backwards pulse from SR..BP the register field SR..D8 shifts the content of all
register fields one place back and accepts the 10 from SR..I2.
Transfer of value
– SR..EN is activated, the function block is active.
– SR..I2 has the value 52.
– With the backwards pulse from SR..BP the register field SR..D8 shifts the content of all
register fields one place back and accepts the 52 from SR..I2.
Reset of the register
– SR..EN is activated, the function block is active.
– Activating SR..RE clears the content of the register.
The function block and its parameters
Function block inputs
Description
Note
(Bit)
EN
1: Activates the function block.
The checkbox for the
Function block release by EN is
necessary
parameter must first be enabled
FP
Forward Pulse
Single
Clock input, shift register forward
BP
Backward Pulse
Clock input, shift register backward
RE
Reset
1 clears the entire output register Q1...Q8 and
D1...D8.
328
easyE4
11/18 MN050009 EN www.eaton.com
Содержание easyE4 series
Страница 1: ...Manual 11 18 MN050009 EN easyE4 Manual...
Страница 4: ......
Страница 16: ...12 easyE4 11 18 MN050009 EN www eaton com...
Страница 22: ...0 1 About this manual 18 easyE4 11 18 MN050009 EN www eaton com...
Страница 40: ...1 easyE4 control relays description 1 10 Safety regulations 36 easyE4 11 18 MN050009 EN www eaton com...
Страница 169: ...easyE4 11 18 MN050009 EN www eaton com 165...
Страница 462: ...6 Function blocks 6 4 Timing and counter relay example 458 easyE4 11 18 MN050009 EN www eaton com...
Страница 490: ...7 System settings 7 16 Time and Date setting 486 easyE4 11 18 MN050009 EN www eaton com...
Страница 520: ...9 easyE4 inside 9 7 NET network 516 easyE4 11 18 MN050009 EN www eaton com...
Страница 524: ...10 Diagnostics messages of the operating system 10 2 Diagnostics buffer 520 easyE4 11 18 MN050009 EN www eaton com...
Страница 570: ...11 Connection to other devices 11 6 E mail function 566 easyE4 11 18 MN050009 EN www eaton com...
Страница 578: ...12 Faults 12 4 Functionality of the NET faulty 574 easyE4 11 18 MN050009 EN www eaton com...
Страница 582: ...13 Maintenance 13 3 Storage transport and disposal 578 easyE4 11 18 MN050009 EN www eaton com...
Страница 594: ...590 easyE4 11 18 MN050009 EN www eaton com...
Страница 614: ...610 easyE4 11 18 MN050009 EN www eaton com...