8 800 Settings
8.4 Configurator
312
Control Relay easy800
11/11 MN04902001Z-EN
www.eaton.com
8.4 Configurator
Call the configurator in the System menu. The following menu items vary
according to the device or the connected periphery.
NET
A description of how to parameterize and configure the easyNet network is
provided in,
LINK
In this menu you assign parameters to a configurable local expansion unit
that is connected to the easyLink terminal of the easy800 standard. The
menu is only accessible if this type of local expansion unit is connected.
easy800-SWD does not have this feature..
The configurable expansion units include the bus modules such as EASY
204-DP and the EASY4..-DC-ME analog expansion units.
Configuring the bus module
With a bus module you only configure the address via which it is to be
accessed on the fieldbus. The relevant operator manual for the bus module
provides the relevant information.
Configuring analog expansion units
How to configure analog expansion devices,
Section “Configuring the analog expansion unit“, Page 84.
ETHERNET-GW
This menu is used to assign parameters for an EASY209-SE Ethernet
gateway that is connected to the serial interface.
Basic requirements:
•
The easy800 device is in STOP operating mode.
•
easy800 standard and the Ethernet gateway are interconnected via the
EASY800-MO-CAB connection cable. To connect easy800-SWD use the
EU4A-RJ45-CAB2 connection cable.
The following table shows the available parameters and their factory settings
for an Ethernet coupling unit.
The description of the parameters is provided in the operating manual for
the Ethernet gateway AWB2528-1596., chapter Configuration via the RS232
interface and in the Help system of easySoft-Pro.
NET
LINK
ETHERNET_GW...
→
An EASY209-SE Ethernet gateway can be run on easy800
standard from device version 10 and on an easy800-SWD from
device version 01.
Содержание easy800
Страница 1: ...11 11 MN04902001Z EN replaces AWB2528 1423GB Manual Control Relay 800 4 patpks nycmyn...
Страница 4: ...2...
Страница 16: ...0 About This Manual 0 5 Writing conventions 12 Control Relay easy800 11 11 MN04902001Z EN www eaton com...
Страница 138: ...4 Wiring with 800 4 7 Working with function blocks 134 Control Relay easy800 11 11 MN04902001Z EN www eaton com...
Страница 300: ...7 SmartWire DT 7 4 Errors on the SWD line 296 Control Relay easy800 11 11 MN04902001Z EN www eaton com...
Страница 336: ...10 Diagnostics possibilities 10 4 Transistor output 332 Control Relay easy800 11 11 MN04902001Z EN www eaton com...