Operating instructions

Transformer Switching Relay TSRL

Summary of Contents for TSRL

Page 1: ...1 4 FSM AG Erich Rieder Straße 2 D 79199 Kirchzarten vertrieb fsm ag www fsm ag 18 10 2018 1 8 Operating instructions Transformer Switching Relay TSRL ...

Page 2: ...ilure recognition 4 1 4 3 Dimming Special version 4 2 Notes for your safety 4 3 Set up and installation 4 3 1 Scope of delivery 4 3 2 Connections and operating elements 5 3 3 Installation 5 3 4 Set up 5 4 Operation 5 4 1 Potentiometer TP1 5 4 2 Potentiometer setting 6 4 3 Adjustments using a packet core transformer as an example 6 5 Maintenance and service 6 6 Troubleshooting guide 6 7 Accessories...

Page 3: ...ent and traction transformers The TSRL is solely intended for installation in a closed device Outside mounting is not allowed Please ensure correct connection assignment see chapter 3 2 Connections and operating elements Please note the technical datas on the type lable 1 4 Functions The TSRL is an electronic device for switching of transformers It allows inrush free switching of one or multiple s...

Page 4: ...o be switched smoothly In this case the voltage impulses are continuously increased up to the potentiometer TP1 set values before complete switching 2 Notes for your safety Danger The guidelines contained in this book need to be read and followed to ensure safe operation To avoid injury and material damage the device must be installed and operated under conditions and within limits as listed under...

Page 5: ... s primary current with the TSRL s load current Please ensure compatibility of the control input with the intended circuit Please note that the control input of the TSRL s standard version is connected to mains potential Adjust the potentiometer TP1 to the utilized type of transformer When using the control input please switch control input to Off before applying main voltage 4 Operation 4 1 Poten...

Page 6: ...ht Large negative magnetisation currrent peaks are visible 5 Maintenance and service For the TSRL no special maintenance is needed It is recommended to check and if necessary retighten the connection termi nal regularly Use dry compressed air to remove dust deposits For that make sure mains voltage is turned off 6 Troubleshooting guide If malfunctions occur while installation or operation of the d...

Page 7: ... spare parts available The TSRL can only be completely replaced or repaired 8 Technical data Technical data can be found in the corresponding data sheet which is available at www fsm ag or can be downloaded using the QR code below 8 1 Dimensions All dimensions in mm 2 5 45 5 11 44 25 63 5 61 D3 2 77 5 89 5 99 3 82 85 D4 5 3 2 5 45 5 11 44 25 63 5 61 D3 2 77 5 89 5 99 3 82 85 D4 5 35 107 88 ø ø ...

Page 8: ...1 mit Halbwellenausfall Erkennung 1 Steuereingang für Schließerkontakt Steuereingang 2 Steuereingang für Steuerspannung Nennstrom 2 16 A Externes Potentiometer 0 internes Poetentiometer 1 externes Potentiometer Sonderversions Nummer wird vom Hersteller vergeben 00 Standardversion Bauform 1 Platine zumEinbau 2 Gehäuse für Wandmontage 3 Gehäuse für Normschienenhalter Special version number supplied ...