MN05401004E
5
english
Count Frequency
Frequency measurement (INP C):
Error:
< 0.1 %
Measuring principle:
< 38 Hz:
period measurement
> 38 Hz:
gating time measurement
gating time = 26.3 ms
Input sensitivity:
Standard sensitivity:
DC power supply
Low: 0 – 0.2 x U
B
[V DC]
High: 0.6 x U
B
– 30 [V DC]
U
B
= Voltage Supply
5V sensitivity:
Low: 0 – 2V DC
High: 4 – 30V DC
Pulse shape:
any*, Schmitt-Trigger inputs
Ambient temperature:
-20 to +65°C [-4 to 149°F]
Storage temperature:
-25 to +70°C [-9 to 158°F]
EMC:
In compliance with the
EC Directive
2004/108/EEC
Noise emission
EN 61 000-6-3/
EN 55 011 Class B
Noise immunity
EN 61 000-6-2
Housing:
For front panel mounting: 48 x 24 mm
[1.89 x 0.94 in.] acc. to DIN 43700, RAL7021,
dark grey
Weight:
appr. 50 g [1.76 oz.]
Front panel rating:
IP 65
* at maximum frequency (50-50 duty cycle)
Cleaning:
The front of the unit is to be cleaned only with a
soft cloth moistened with water.
7. Terminal assignment
1
10 – 30V DC
2
0V GND
3
INP A
4
INP B
5
INP C
8. Contents:
1 Digital display
1 Panel mounting clip
1 Bezel for screw mounting, panel cut out
50 x 25 mm [1.97 x 0.98 in.]
1 Bezel for clip mounting, panel cut out
50 x 25 mm [1.97 x 0.98 in.]
1 Seal
1 Multilingual operating instructions
DC power supply:
24V
12V
Input level:
Standard
typ. low level:
2.5V
2.0V
typ. high level:
22.0V
10V
Fmax:
kHz
kHz
ContDir/Tacho
30
10
UpDown/Tacho
10
10
Up.Up/Tacho
10
10
Quad 1/Tacho
15
10
Quad 2/Tacho
15
10
Quad 4/Tacho
10
8
Содержание E5024E0432